  • Right click on the Profiles object and select New SIP SGP. Change the SIP Profile ID to something other than ID:0. By doing this, the other fields within the SIP SGP object can now be modified.

  • In the SIP SGP object enter a name in the SIP Profile Name field to identify this profile.

  • Right click on the SIP SGP object just created and select New SIP ISUP CPC Mapping. A SIP ISUP CPC Mapping object will appear. Refer to IMG 1010 - SIP ISUP CPC Mapping (10.5.1_ER1 and above) topic for information on configuring the object.

...

  • Right Click on 2020 IMG Name and select New Signaling. The Signaling Object allows multiple signaling objects to be configured below it. No configuration is needed in this object.

  • Right Click on Signaling Object just created and select New SIP. Select the SIP SGP created above from drop down menu in the Remote IMG's SIP Profile field. For more information refer to the IMG 1010 - SIP Signaling Object topic.

Create an External Gateway

...

  • Right click on the IMG EMS object and select New External Network Elements. The External Network Elements object allows multiple external network element objects to be created under it. There is no configuration required in this object. Refer to the IMG 1010 - External Network Elements topic for more information.

  • Right click on External Network Elements object and select New External Gateways. The External Gateways object allows multiple gateway objects to be created under it. There is no configuration required in this object. Refer to the IMG 1010 - External Gateways topic for more information.

  • Right click on External Gateways object and select New External Gateway. Enter a name in the Name field to identify the gateway being created.

  • Select SIP from drop down menu in the Gateway Signaling Protocol field.

  • Enter an IP address for this gateway.

  • In the SIP Profile field the SIP SGP configured earlier can be selected from drop down menu.

...

  • Right click on the IMG EMS object and select New Routing Configuration. Refer to the IMG 1010 - Routing Configuration Object topic for more information.

  • Right click on Routing Configuration and select New Channel Groups. The Channel Groups object allows multiple channel groups to be created under it. There is no configuration required in this object. Refer to the IMG 1010 - Channel Groups topic for more information on this object.

  • Right click on Channel Groups object and select New Channel Group. Enter a name to identify this channel group and change the Signaling Type to SIP using the drop down menu. Refer to the IMG 1010 - Channel Group topic for more information on configuring a SIP channel group.

...