The IMG supports up to 66 total Route/Cause Code/Service Routing Tables per EMS. Each table can support up to 5000 entries. The IMG has a max capacity of 100,000 entries, or 20 tables each with 5000 entries.* Each IMG supports 4 route tables unique to the system, allowing the GateControl EMS to control, monitor, and maintain 250 discrete gateways.
Route tables can be specific to a particular gateway, or they can be global.
Route verification See IMG 1010 - Validating Your Configuration
Ability to import a .csv file to be used for routing and translation tables.
Route from one route table to another with the ability to prevent looping.
Configure the IMG to accept calls from multiple gateways with one External Gateway Entry (Gateway Mask field).
Translation
Appending Info Digits
Translation based on Channel Group
ANI and DNIS Translation
...