Pre-requisite to Configuring SS7 Redundancy:

...

Configure Redundant SS7 Signaling on the Primary IMG

See IMG 1010 - Configuring SS7 Signaling - 10.5.0 for the general procedure, setting specific fields in panes as noted below.

...

  • SS7 Signaling (See paragraph "Creating an SS7 Signaling Entry" on page IMG 1010 - Configuring SS7 Signaling - 10.5.0)

    • In the Redundancy Configuration field, select Primary.

    • In the Peer Logical Node ID field, select the secondary IMG. If there is only one other IMG in the Logical IMG it will be automatically populated with that Node.

...

  • Primary SS7 Links (See paragraph "Configuring SS7 Signaling Links" on page IMG 1010 - Configuring SS7 Signaling - 10.5.0)

    • In the Primary/Secondary field select Primary.

    • The Link ID field drop-down will include ID's 0-63, and will be populated with the first available number.

    • The Interface - Offset field drop-down will include spans configured on the Primary IMG and default to the first available span.

...

Info

The configuration of these links are done in ClientView on the Primary IMG as the SS7 Stack is configured on the primary IMG only.

...