Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Appliance Power Specifications

Electrical Parameters

SYS40 (SMB SBC/PBXact 40)

SYS60/100 (PBXact 60 and Vega Enteprise SBC 25-250 calls)

SYS75

SYS400 (PBXact 400)

SYS1200 (PBXact 1200)

SYS2001 (PBXact 2001)

Input Voltage

90-264 VAC

90-264 VAC

90-264 VAC

90-264 VAC

90-264 VAC

100 - 240Vac

AC Frequency

43-90 Hz

43-90 Hz

43-90 Hz

43-90 Hz

43-90 Hz

50-60 Hz

Power consumption

Max: 21.8W
Idle: 7.0 W

Max: 20.0W
Idle: 11.5 W

Max: 19.8W
Idle: 11.3 W

Max: 77.0W
Idle: 36.37W

Max: 77.0W
Idle: 36.37W

Max: ~80.0W
Idle: ~35.00W

Heat

Max: 74.4 Btu/h
Idle:23.9 Btu/h

Max: 68.2 Btu/h
Idle:39.2 Btu/h

Max: 67.5 Btu/h
Idle:38.6 Btu/h

Max: 262.7 Btu/h
Idle:124.1 Btu/h

Max: 262.7 Btu/h
Idle:124.1 Btu/h

Max: ~70 Btu/h
Idle: ~40 Btu/h

Power Supply

Rated Power 12V 5A

Rated Power 12V 5A

Rated Power 12V 5A

Rated Power 110/220W ATX

Rated Power 110/220W ATX

350W/550W

Air Flow

Heat sink

Duty Cycle 100%=0.3192 m3/min 

Duty Cycle 100%=0.5275 m3/min

Duty Cycle 100%=1.0192 m3/min

Duty Cycle 100%=1.0192 m3/min

Duty Cycle 100%=~1 m3/min depending on fan quantity

Climate data

Working Temperature

-10-60℃

-10-60℃

-10-60℃

-10-60℃

-10-60℃

5-35℃

Stock Temperature

-20-70℃

-20-70℃

-20-70℃

-20-70℃

-20-70℃

-40-70℃

Humidity

5%-95% Relative Humidity, Non Condensing

5%-95% Relative Humidity, Non Condensing

5%-95% Relative Humidity, Non Condensing

5%-95% Relative Humidity, Non Condensing

5%-95% Relative Humidity, Non Condensing

5%-95% Relative Humidity, Non Condensing

...