*A manual firmware upgrade is required to use the above 1.2.x releases for cards 
purchased before November 10th, 2010 
--> Firmware upgrade Procedure 

...

Hardware Installation

  1. Mount your transcoder
    -> D150-ETH-Find a free PCI slot insider a server to install
    -> D150-BOX- Find a well ventilated flat surface, or install in optional rack mount
    ---------

  2. Attach Power supply
    -> D150-ETH- use molex power from server power supply 2A @ 5V (10W),
                         or external power supply 2A @ 5V (10W)
    -> D150-BOX- external power supply 2A @ 5V (10W)
    ---------

  3. Plug the Ethernet cable into your transcoder to attach to your network
    * Note: There is no on-board Ethernet switch on the D150, so once plugging in the Ethernet Cable, there is direct access to the transcoding module

...

*Note: This step assumes FreeSWITCH is on the same server as the server hosting the sngtc_server. If FreeSWITCH  only exists on other server(s) please go to -> D150 sngtc server configuration

The Sangoma FreeSWITCH codec is part of the FreeSWITCH git repository.  It can be easily attained by running the following command in linux CLI:

...

By default G729 is the only codec registered with FreeSWITCH.  If you require additional codecs please go to the FreeSWITCH Codec Configuration page

...

Operation

  • The sngtc_server needs to be started before transcoding can be done. Below is the usage of the sngtc_server_ctrl command. 

...

*Note by default this script is started on system boot. 

 

  • To enable FreeSWITCH to connect to the sngtc_server and then to the transcoder you will need to have the module mod_sangoma_codec loaded. To load the module run the command below.

...