Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Disconnect Supervision for Vega50/5000

Problem

In a scenario when in the inbound call : Legacy PBX > Vega > Asterisk - The PBX side initiates the disconnect, but Vega doesn't disconnect.

...

  1. Polarity Reversal - The first step will be to try enabling Polarity Reversal option.
    In the WebGUI please navigate to: Expert Config > POTS > FXO Port Hardware Profiles > Line Reversal - mark it as ON
    Apply + Save + Test
    Note: This may not work outside of the UK

  2. Loop Current - If step 1 didn't work for you, then you can try to change the Loop Current
    In the WebGUI please navigate to: Expert Config > POTS > FXO Port Hardware Profiles > Loop Current Detect change from 0 to 300 or/and 500
    Apply + Save + Test

  3. Tone Detection - If the above two methods didn't work for you, then you can try to adjust the Tones.
    In the WebGUI please navigate to: Expert Config > Tones > Tone Detection > Mark Enabled
    Apply + Save + Test