IMG 1010 - E1 CAS Timers
Timer ID | Description: (State Used); Timer Description | Default Value |
---|---|---|
1 | (S19) Incoming Layer 4 busy out Acknowledge wait | 4000 |
2 | (S2) Incoming Stage 1 FWD digit receive wait | 20000 |
3 | (S3) Incoming Stage 2 FWD digit receive wait | 20000 |
4 | (S4) Incoming Stage 3 FWD digit receive wait | 20000 |
5 | (S5) Incoming Stage 4 FWD digit receive wait | 20000 |
6 | (S13) Layer 4 Connect wait | 24,0000 |
7 | (S14) Layer 4 wait | 4000 |
8 | (S21) Clear Forward (idle line signaling) wait | 15000 |
9 | (S3) Incoming Stage 2 Initial FWD digit receive wait | 20000 |
10 | (S2) Incoming Stage 1 Initial FWD digit receive wait | 20000 |
11 | (S5) Incoming Stage 4 Initial FWD digit receive wait | 20000 |
12 | (S4) Incoming Stage 3 Initial FWD digit receive wait 2000 | 20000 |
13 | (S15) Layer 3 Circuit Release wait | 100 |
14 | (S18) Layer 3 Circuit Release wait | 100 |
15 | (S6) Host Control Wait | 60000 |
16 | (S13) Layer 3 Connect wait | 240000 |
17 | (S29) Seize Acknowledge wait | 4000 |
18 | (S31) Time to wait before transmitting idle signal after detecting glare | 100 |
19 | (S32) Time to wait before looking for idle signal after transmitting idle signal after detecting glare | 100 |
20 | (S39) Outgoing Stage 1 BWD R2 signal wait | 15000 |
21 | (S39) Outgoing Stage 1 Initial BWD R2 signal wait | 15000 |
22 | (S41) Outgoing Stage 2 BWD R2 signal wait | 15000 |
23 | (S41) Outgoing Stage 2 Initial BWD R2 signal wait | 15000 |
24 | (S43) Outgoing Stage 3 BWD R2 signal wait | 15000 |
25 | (S43) Outgoing Stage 3 Initial BWD R2 signal wait | 15000 |
26 | (S45) Outgoing Stage 4 BWD R2 signal wait | 15000 |
27 | (S45) Outgoing Stage 4 Initial BWD R2 signal wait | 15000 |
28 | (S46) Outgoing wait for answer | 24000 |
29 | (S48) Outgoing Layer 4 Clear wait | 4000 |
30 | (S49) Outgoing idle line signal wait | 120000 |
31 | (S50) Outgoing idle line signal wait after glare detected | 120000 |
32 | (S24) Host Control wait | 240000 |
33 | (S33) Time to wait for Clear Forward after glare detected | 10000 |
34 | Receive line signaling filter | 40 |
36 | (S6, S24) Incoming BWD R2 Cycle Complete Event wait | 4000 |
38 | (S10) Time to wait for idle line signaling after invalid line signal detected while receiving FWD R2 digits | 20000 |
39 | (S22) Layer 3 Clear Forward wait | 3000 |
40 | (S39) Outgoing Stage 1 BWD A signal wait after sending all of Stage 1 FWD digits | 20000 |
41 | (S2, S3, S4, S5) FWD R2 digits receive wait when String Collection Data field in Inpulsing Parameters Configure is set to 0xFF | 200 |
43 | R2 Cycle Complete Event wait | 2000 |
45 | (S43) Time to wait for next BWD R2 signal when stage 3 digits have been outpulsed | 20000 |
...