IMG 1010 - Configuring a Bearer Span - 10.3.x
Configuring a T1 or E1 Bearer Span (Software 10.3.x)
Prerequisite:
Procedure:
Right Click on the IMG Name: xxx ID:0 and select New Facility. A Facility Pane will appear. This is a monitoring object in ClientView and no configuration is needed.
Right-click Facility and select New TDM DS1. A ClientView Pane like below will appear.
Trunk Type: This is automatically populated with the Trunk Type that your IMG is configured for. (T1 or E1)
Component ID: Select from a drop down menu whether this span will be on a Bearer Span or a Signaling Span.
Interface ID: Select from a drop down menu the span you would like to configure. This field will automatically populate the next available span
Once all selections have been made, commit this object.
The next step is to create a physical T1/E1 span. See IMG 1010 - T1 Physical Span - 10.3.x or IMG 1010 - E1 Physical Span - 10.3.x link on how to accomplish this.