Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Table of Contents
minLevel1
maxLevel6
outlinefalse
stylenone
typelist
printablefalse

Task Summary

Configuring SS7 CIC routing involves the following tasks:

...

  • To add ISUP groups to the SS7 Channel Group, right-click the SS7 Channel Group you created and select New ISUP Group. The ISUP Group pane appears.

    Image RemovedImage Added
  • Ensure that the OPC-DPC that defaults in is correct. These values come from the Stack ID and the associated SS7 Route. You associate the stack with the ISUP Group here.

  • Select entries in all fields as required. See the ISUP Group GUI Reference for a description of each field.

...

  • Right-click the SS7 ISUP Group entry and select New FCI Override. The FCI Override pane appears.

  • Enable FCI Override by selecting Override in the FCI Override field.

  • Select the desired override value for each parameter.

See IMG 1010 - FCI Override for details.

 

Configuring TMR-USI Override

...

  • Right-click the SS7 ISUP Group entry and select NewTMR_USI Override. The TMR-USI Override pane appears.

  • Make selections in each field as required.

See IMG 1010 - TMR-USI Override for details.

Configuring Location Override

  • Right-click the SS7 ISUP Group entry and select New Location Override. The Location Override pane appears.

  • In the Location Override field, select Override.

  • If required, change defaults in the Location and Coding Standard fields

See IMG 1010 - Location Override for details.  

 

Assigning SS7 Circuits to an ISUP Group ( CICs)

  • Right-click the ISUP Group you created and select New Circuits. The Circuit pane appears.

  • In the IMG Name field, select the physical IMG.

  • In the IMG Interface field, select Bearer or Signaling.

  • In the Start Interface Offset field, enter a value from 0-27 to define where the CICs are going out of the IMG. Make sure this value matches the Interface ID defined for the physical spans. That is, make sure bearer CICs go out over bearer spans and signaling CICs go out over signaling spans.

  • In the Trunk Type field, select T1 or E1. Make sure this matches what you defined for physical spans).

  • In the Start Channel field, select the first channel where the CICs will get assigned.

  • In the Start CIC field, enter the first CIC in the group.

  • In the CIC Count field, enter the total number of CICs in the group.

See IMG 1010 - Circuit Group for a description of each field.

...

  • Right-click the ISUP Group that you created and select New SS7 Parameter Filter. The SS7 Parameter Filter pane appears.

    Image RemovedImage Added
  • If you want to change the default for any of the parameters, select the desired setting from its drop-down list.  
     

Related Topic

IMG 1010 - Provisioning CICs