Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Description:
You can configure various H.225 and H.245 timers used in H.323 Signaling.
Info |
---|
If you make changes to the default timer values and then later delete the H.323 Timer object and then create a new one, the timer values will not be reset to the default values but will retain the values you entered. If you wish to revert to the default values you must do so manually. |
Accessing this Pane
Dialogic IMG EMS -> Logical IMG -> Physical IMG -> Signaling -> H323 Signaling -> H323 Timers
...
1 per H.323 Signaling object
Related Topics:
IMG 1010 - Configuring H.323 Signaling
Technical Notes:
When configuring H323 Timers, the following happens:
...
ClientView Pane:
...
Field Descriptions:
Info |
---|
To change any of the following Timers, click in the individual field and enter the new value. |
H225 T301 (10 ms):
Timer T301 defines how long the calling element shall wait for the called element to respond. This timer starts when Alerting is received and normally terminates on Connect or when the caller terminates the call attempt and sends Release Complete. The valid range of values is 18000-65000 (10 ms).
...