IMG 1010 - Configuring a Bearer Span - 10.3.x

Configuring a T1 or E1 Bearer Span (Software 10.3.x)

Prerequisite:

IMG 1010 - Facility

...

  • Right Click on the IMG Name: xxx ID:0 and select New Facility. A Facility Pane will appear. This is a monitoring object in ClientView and no configuration is needed.

  • Right-click Facility and select New TDM DS1. A ClientView Pane like below will appear.

    Image RemovedImage Added
    • Trunk Type: This is automatically populated with the Trunk Type that your IMG is configured for. (T1 or E1)

    • Component ID: Select from a drop down menu whether this span will be on a Bearer Span or a Signaling Span.

    • Interface ID: Select from a drop down menu the span you would like to configure. This field will automatically populate the next available span

  • Once all selections have been made, commit this object.

  • The next step is to create a physical T1/E1 span. See IMG 1010 - T1 Physical Span - 10.3.x or IMG 1010 - E1 Physical Span - 10.3.x link on how to accomplish this.