Table of Contents | ||
---|---|---|
|
Overview
Release R111S019/R120S005 onwards , VEGA will have capability to tap DSP from VEGA GUI.
...
Info |
---|
ALERT
|
Start DSP TAP Capture
In order to start dsp tap from VEGA GUI there are multiple steps involved as provided below:
As shown in below screen shot, User need to go to "DSP Capture" option as prevent with in "Reports" section
i.e. GUI → Report→ DSP Capture as provided below:Now, user has to select the DSP channel on which call is present and DSP TAP has to be captured. Once the user selects the DSP channel on which TAP needs to be captured press start in order to start DSP TAP trace in that DSP channel.
In below example user is trying to capture DSP TAP on dsp channel 1 where call is active:
Once the DSP TAP is started on the user specified DSP channel, a pop-up windows showing the DSP status will appear on to the screen also, the DSP Capture Windows also provides intimation to user on which DSP port/channel Tap is running as shown below:
Stop DSP TAP Capture
In order to stop dsp tap from VEGA GUI there are multiple steps involved as provided below:
...
Info |
---|
NOTE User has to wait for around one minute in order to get DSP Stop process complete and once DSP Tap stop process is complete then only user should go ahead and disconnect the call. |
Download DSP TAP Capture
Once DSP TAP trace is properly stopped. Now, DSP TAP trace is available for user to download the same as present on he DSP Capture Window
...
Once the DSP Tap trace is downloaded please provide the same to sangoma support for further analysis.
Clear DSP TAP Capture
User can even clear DSP TAP trace captured on VEGA once user is done with it by clicking on the Trace Clear option as present within the DSP Capture Windows as shown below:
...
Once the DSP Tap is clear now User will not be able to get Download/Clear Trace Option until user again start the process of DSP TAP capture.
Important Information
Warning |
---|
Important Things to Remember while using DSP Trace
|