Overview:

To enable the IMG to function over an IP network the VoIP modules must be configured. There are two steps involved in configuring each VoIP module. The first step is to configure the IP Address (Interface). Below are screen captures of both the IMG 1010 and IMG 1004 and their respective DATA 0 port locations (IP Address-Interface).  Once the Network Interface is configured the VoIP module(s) must be configured to communicate with the Network Interface. This is accomplished under the Facilities object. The procedure below describes the steps needed to configure the network interface DATA 0 so it communicates with VoIP Module 0.

IMG1010 Rear Panel Data 0 location

IMG1004 Rear Panel Data location

 Procedure

Create Network Interface

The IMG 1010 has VOIP Module 0 for one of selections in the Physical Interface field and the IMG 1004 has VoIP Processor. The reason for the name discrepancy is that the IMG 1010 has two VoIP Modules with the Processors embedded on each Module. These modules are removable. The IMG 1004 has the VoIP Processer embedded on the motherboard and cannot be removed.

 

IMG 1010 IP Address Object Pane

 IMG 1004 IP Address Object Pane

Create IP Bearer (VoIP Resource)

Create an IP Bearer facility. This facility will be tied to port DATA 0 (VoIP Resource) and the VoIP Module 0 created earlier.