Complete the following steps to remove and replace the fuse.
Warning !!! Â |
|
|
Â
Important Notes
Replace the fuse with only a Sangoma-supplied fuse or equivalent:
2.0 Amp; Slow Blow, type 3AG. ÂFor safety, the integrated fuse can only be replaced when the power cord is removed.
Â
Procedure
Ensure the power switch on the AC power module is set to O (OFF).
Unplug AC power cord from the wall outlet.
Using a small flat bladed screwdriver, open the hinged fuse cover on the AC Power Module. The fuse holder and fuse are located behind this cover.
Remove the fuse holder located behind the cover on AC Power Module using a small flat bladed screwdriver. The fuse is mounted within the fuse holder just removed in previous step.
Remove the blown fuse from the fuse holder and reinstall the new fuse. The fuse only mounts on one side of the cartridge.
Install the fuse holder into the AC power module with the fuse facing down.
Close cover.
Reinsert power cable into power module located at rear of IMG 1004.
Plug AC cord removed in step 2 back into the wall outlet.
Toggle the power switch on the AC Power Module back to 1 (ON) position. IMG 1004 should now power up.