Dialogic IMG - IMG 1010 - T1 CAS Filters and Timers
Table of Contents
Signal Scanning Filters
Signal Scanning Filters define the duration that an expected signaling condition is expected to be valid before it is declared to have occurred. Filter values are entered in the IMG 1010 - Filter/Timer Configure pane in millisecond decimal units. Filter Values however are sent to the IMG in 10 millisecond units. Therefore they must be entered in 10 ms increments. If there is no value in a field, the timer does not apply.
Timer No. | Signal Scanning Filter | E&M | FXS-LS |
|---|---|---|---|
0x01 | Preseize | 100 |
|
0x02 | Inseize | 150 | 200 |
0x03 | Modified Incoming Release | 700 | 700 |
0x04 | Modified Outgoing Release | 700 | 700 |
0x05 | Normal Incoming Release | 700 | 700 |
0x06 | Normal Incoming Release w/Flash | 1020 | 1020 |
0x07 | Normal Outgoing Release | 700 | 700 |
0x08 | Normal Outgoing Release w/Flash | 1020 | 1020 |
0x09 | Post Inseize Acknowledgment |
|
|
0x0A | Outseize Acknowledgment | 100 | 180 |
0x0B | Outseize Answer | 350 |
|
0x0C | Outseize Dial Signal End | 40 |
|
0x0D | First Release | 700 | 700 |
0x0E | ANI Req Offhook | 200 | 200 |
Signal Scanning Timers
Signal Scanning Timers (table below) define the minimum and maximum acceptable durations for signaling condition to exist from the point they are declared valid.
Timer No. | Signal Scanning Timer | E&M | FXO-LS | FXS-LS | FXO-GS | FXS-GS |
|---|---|---|---|---|---|---|
0x15 | Inseize Complete |
|
|
| 6040 |
|
0x16 | Post Inseize Complete |
|
|
|
| 220 |
0x17 | Start Normal Outgoing Release | 0 |
|
|
|
|
0x18 | Start Normal Incoming Release | 0 |
|
|
|
|
0x19 | Outseizure Acknowledgment | 5000 |
|
| 5000 | 6000 |
0x1A | Outseizure Answer | 100,000 |
| 640,000 |
|
|
0x1B | Guard Time-out | 700 | 850 |
| 850 |
|
0x1C | Release | 320,000 |
| 320,000 | 320,000 | 320,000 |
0x1D | Glare Detection | 100 | 300 |
| 100 |
|
0x1E | Minimum Flash | 300 | 300 | 300 | 300 | 300 |
0x1F | Maximum Flash | 1000 | 1000 | 1000 | 1000 | 1000 |
0x20 | Start Dial (Wink 1) Minimum Wink | 100 |
|
|
|
|
0x21 | Start Dial (Wink 2) Maximum Wink | 350 |
|
|
|
|
0x22 | Minimum Delay Dial Signal | 140 |
|
|
|
|
0x23 | Maximum Delay Dial Signal | 4000 |
|
|
|
|
0x24 | Post Start Dial Signal Outpulse Delay | 80 |
|
|
|
|
0x25 | Wink 2 Minimum Receive Duration | 100 |
|
|
|
|
0x26 | Wink 2 Maximum Receive Duration | 500 |
|
|
|
|
0x27 | Wink 2 Minimum Post Outpulse Delay | 100 |
|
|
|
|
0x28 | Wink 2 Maximum Post Outpulse Delay | 3500 |
|
|
|
|
0x29 | Wink 2 Maximum Receive Detection | 11,500 |
|
|
|
|
0x2A | Wink 3 Minimum Receive Duration | 100 |
|
|
|
|
0x2B | Wink 3 Maximum Receive Duration | 600 |
|
|
|
|
0x2C | Wink 3 Minimum Post Outpulse Delay | 100 |
|
|
|
|
0x2D | Wink 3 Maximum Post Outpulse Delay | 3500 |
|
|
|
|
0x2E | Wink 3 Maximum Receive Detection | 4,000 |
|
|
|
|
0x2F | Wink 4 Minimum Receive Duration | 100 |
|
|
|
|
0x30 | Wink 4 Maximum Receive Duration | 350 |
|
|
|
|
0x31 | Wink 4 Minimum Post Outpulse Delay | 100 |
|
|
|
|
0x32 | Wink 4 Maximum Post Outpulse Delay | 3,500 |
|
|
|
|
0x33 | Wink 4 Maximum Receive Detection | 4,000 |
|
|
|
|
0x34 | Wink 5 Minimum Receive Duration | 100 |
|
|
|
|
0x35 | Wink 5 Maximum Receive Duration | 350 |
|
|
|
|
0x36 | Wink 5 Minimum Post Outpulse Delay | 100 |
|
|
|
|
0x37 | Wink 5 Maximum Post Outpulse Delay | 3,500 |
|
|
|
Return to Documentation Home | Sangoma Support