Signal Scanning Filters

Signal Scanning Filters define the duration that an expected signaling condition is expected to be valid before it is declared to have occurred. Filter values are entered in the IMG 1010 - Filter/Timer Configure pane in millisecond decimal units. Filter Values however are sent to the IMG in 10 millisecond units. Therefore they must be entered in 10 ms increments. If there is no value in a field, the timer does not apply.

Timer No.

Signal Scanning Filter

E&M

FXS-LS

Timer No.

Signal Scanning Filter

E&M

FXS-LS

0x01

Preseize

100

 

0x02

Inseize

150

200

0x03

Modified Incoming Release

700  

700

0x04

Modified Outgoing Release

700  

700

0x05

Normal Incoming Release

700

700

0x06

Normal Incoming Release w/Flash

1020

1020

0x07

Normal Outgoing Release

700   

700

0x08

Normal Outgoing Release w/Flash

1020

1020

0x09

Post Inseize Acknowledgment

 

 

0x0A

Outseize Acknowledgment

100   

180

0x0B

Outseize Answer

350

 

0x0C

Outseize Dial Signal End

40

 

0x0D

First Release

700   

700

0x0E

ANI Req Offhook

200

200

Signal Scanning Timers

Signal Scanning Timers (table below) define the minimum and maximum acceptable durations for signaling condition to exist from the point they are declared valid.

Timer No.

Signal Scanning Timer

E&M

FXO-LS

FXS-LS

FXO-GS

FXS-GS

Timer No.

Signal Scanning Timer

E&M

FXO-LS

FXS-LS

FXO-GS

FXS-GS

0x15

Inseize Complete

 

 

 

6040

 

0x16

Post Inseize Complete

 

 

 

 

220

0x17

Start Normal Outgoing Release

0

 

 

 

 

0x18

Start Normal Incoming Release

0

 

 

 

 

0x19

Outseizure Acknowledgment

5000

 

 

5000

6000

0x1A

Outseizure Answer

100,000

 

640,000

 

 

0x1B

Guard Time-out

700

850

 

850

 

0x1C

Release

320,000

 

320,000

320,000

320,000

0x1D

Glare Detection

100

300

 

100

 

0x1E

Minimum Flash

300

300

300

300

300

0x1F

Maximum Flash

1000

1000

1000

1000

1000

0x20

Start Dial (Wink 1) Minimum Wink

100

 

 

 

 

0x21

Start Dial (Wink 2) Maximum Wink

350

 

 

 

 

0x22

Minimum Delay Dial Signal

140

 

 

 

 

0x23

Maximum Delay Dial Signal

4000

 

 

 

 

0x24

Post Start Dial Signal Outpulse Delay

80

 

 

 

 

0x25

Wink 2 Minimum Receive Duration

100

 

 

 

 

0x26

Wink 2 Maximum Receive Duration

500

 

 

 

 

0x27

Wink 2 Minimum Post Outpulse Delay

100

 

 

 

 

0x28

Wink 2 Maximum Post Outpulse Delay

3500

 

 

 

 

0x29

Wink 2 Maximum Receive Detection

11,500

 

 

 

 

0x2A

Wink 3 Minimum Receive Duration

100

 

 

 

 

0x2B

Wink 3 Maximum Receive Duration

600

 

 

 

 

0x2C

Wink 3 Minimum Post Outpulse Delay

100

 

 

 

 

0x2D

Wink 3 Maximum Post Outpulse Delay

3500

 

 

 

 

0x2E

Wink 3 Maximum Receive Detection

4,000

 

 

 

 

0x2F

Wink 4 Minimum Receive Duration

100

 

 

 

 

0x30

Wink 4 Maximum Receive Duration

350

 

 

 

 

0x31

Wink 4 Minimum Post Outpulse Delay

100

 

 

 

 

0x32

Wink 4 Maximum Post Outpulse Delay

3,500

 

 

 

 

0x33

Wink 4 Maximum Receive Detection

4,000

 

 

 

 

0x34

Wink 5 Minimum Receive Duration

100

 

 

 

 

0x35

Wink 5 Maximum Receive Duration

350

 

 

 

 

0x36

Wink 5 Minimum Post Outpulse Delay

100

 

 

 

 

0x37

Wink 5 Maximum Post Outpulse Delay

3,500