IMG 1010 - SS7 Link

 

Description:

This object identifies an SS7 link within an SS7 link set to an APC.

Accessing this Pane:

Dialogic IMG EMS -> Logical IMG -> Physical IMG -> SS7  -> SS7 Stack -> SS Link Set -> SS7 link

Maximum Objects:

IMG 1010 = 64 per Logical IMG

IMG 1004 = 4 per Remote Node

 

Note on SS7 Functionality on the IMG 1004: With each new software release Dialogic has added new SS7 functionality to the IMG 1004. See timeline below:

• Release 10.5.1 – Ability to act as a remote SS7 node and terminate up to four links. (F-1406)

• Release 10.5.3 – Full SS7 functionality. (F-1446)

Related Topics:

IMG 1010 - Configuring SS7 Signaling - 10.5.1

Technical Notes:

When configuring a SS7 Link, the following happens:

An SS7 link is assigned on a specific channel/offset. The link will go into the alignment procedure trying to align and come in service.

SS7 Specifications for IMG 1010 and IMG 1004

ClientView Pane :

Field Descriptions:

Primary/Secondary (10.3.x - 10.5.0):

This field specifies whether the SS7 link is supported by the primary or secondary physical IMG.

  • Primary

  • Secondary

Link ID:

This field specifies the SS7 link ID. Select from drop down menu. Link ID 0 – 63 are allowed for the primary physical IMG, while link ID 64 – 127 are allowed for the secondary physical IMG.

IMG (10.5.1+):

This field has a drop down menu with all IMG's configured. Select the Physical IMG that the link being created will be associated with.

Interface - Offset:

This field specifies the physical offset (span) on which the SS7 link will be configured.

Channel:

This field specifies the channel from the physical offset (span) chosen in the previous field on which the SS7 link will be configured.

Signaling Link Code:

This field specifies the SLC of the SS7 link. SLC is unique across any SS7 link set with a range of values of 0 – 15.

Data Rate:

This field specifies the data rate of the SS7 signaling link.

For T1 SS7 links with line coding configured for B7ZS, only the 48 Kbps data rates are valid.

  • 64 Kbps

  • 56 Kbps mask LSB (The Least significant bit is masked resulting in 56 kbps)

  • 56 Kbps mask MSB (The Most significant bit is masked resulting in 56 kbps)

  • 48 Kbps mask LSB and MSB (The Least and Most significant bits are masked resulting in 48 kbps)

  • 48 Kbps mask 2 MSBs (The 2 Most significant bits are masked resulting in 48 kbps)

Electrical Interface:

DS1 Channel

DS1 Channel Data

Monitoring Fields:

Link Status:

This monitoring field displays the status of the SS7 link whether it is in or out of service.

Buttons

In Service:

This buttons brings the SS7 link in service.

Out Of Service:

This buttons takes the SS7 link out of service.

Inhibit:

This buttons inhibits the SS7 link.

UnInhibit:

This buttons uninhibits the SS7 link.

Display Table:

This table displays a list of the configured SS7 links under a specific SS7 Link set.

Return to Documentation Home I Return to Sangoma Support