Media Transcoding Cards - Asterisk D500 LAN Distributed Core Installation

Effective September 30, 2026, these products will reach End of Sale and therefore will no longer be available for purchase.

Effective September 2028, these products will reach End of Life. After this date, regular updates, maintenance, and technical support will be discontinued in accordance with our product lifecycle policy.

For a complete list of the affected SKUs, click HERE.

Media Transcoding Cards - Asterisk D500 LAN Distributed Core Installation

Table of Contents

Transcoding Package

Download the Latest Sangoma Media Transcoding Release:  
---> sng-tc-linux-1.3.8.i686.tgz                   (2016-01-07)             ChangeLog
---> sng-tc-linux-1.3.8.x86_64.tgz             (2016-01-07)

*A manual firmware upgrade is required to use the above 1.2.x releases for cards 
purchased before November 10th, 2010 
--> Firmware upgrade Procedure 


Hardware Installation

  1. Mount your transcoder, then boot the server
    -> choose a server in your network and install the D500 in the PCI Express slot

    *Note: -> The PCI Express slot will server to provide power to the D500, where RTP traffic will flow through the LAN connection
               -> An extra Ethernet interface may be brought up if your server has a Broadcom tg3 driver installed.  Run "ifconfig" to verify.  Disregard this extra interface (bring it down if necessary) as this interface is only used when using PCI Express Single Server installation. 

    ---------

  2. Plug the Ethernet cable into your transcoder to attach to your network


Transcoding package installation

  1. Install the transcoding package on the same server as the D500.

    -> wget <URL of Package>
    -> tar xfz sng-tc-<ver>-<arch>.tgz
    -> cd sng-tc-<arch>-<ver>
    -> make
    -> make install

     

    The D500 transcoder will be detected through the server's Ethernet interface that connects to the network (typically Eth0)
    --------

  2. Firmware Update

    To check if the firmware on the transcoder requires updating run the firmware update utility

    --> Run: sngtc_tool –dev ethX –firmware  (replace ‘X’ with the interface of the network, such as Eth0)
         -> a broadcast message will be sent out Eth0 to any Sangoma transcoders on the network and will detect 
    --> If the FROM and TO version are the same you are up to date so cancel the update; if the versions are different please update.
    --> If the update fails insure the RJ45 is properly connected to the D500 and is illuminated Green colour.  Also verify your firewall/security is not blocking any communication

    * Note sngtc_server must NOT be running during the update; sngtc_server_ctrl stop will stop the server if it is running.

 

-> Please Proceed to Sngtc Server Configuration

<- back to Asterisk D500 main menu