Switchvox - Access Control Rule does not display subnet mask bit on single IP Access Control Rule
SWVX-12468 Access Control Rule does not display subnet mask bit on single IP Access Control Rule
Validation Date: 12/5/2017
Affects Version: 6.5.2 - 6.6.0.4
Resolved Version: 6.7
Description: When creating an Access Control Rule for a single IP (using /32 subnet notation) and saving the rule, the page will display the IP address without the /32 mask bit. This causes an issue where you aren't able to re-save a rule as it sees the entry not in CIDR form. The problem comes from an issue in the UI of Switchvox not properly storing a newly created rule.
Workaround: You can workaround this issue my simply modifying the Access Control Rule, adding /32 to the end, and re-saving. After this the rule should display properly.
Keywords: Access Control Rule /32 ACL