Vega Gateways - Connector Information
The types of connectors present on the gateway varies depending on the model and variant. Pinout information for the telecoms interfaces can be found below.
Single FXS Ports (60G/60Gv2)
Connector required: RJ11 6P2C male plug
Pin | Function |
|---|---|
1 |
|
2 |
|
3 | Tip |
4 | Ring |
5 |
|
6 |
|
Single FXO Ports (60G/60Gv2/3050G)
Connector required: RJ11 6P2C male plug
Pin | Function |
|---|---|
1 |
|
2 |
|
3 | Tip |
4 | Ring |
5 |
|
6 |
|
High Density FXS Ports (3000G/3050G/3050Gv2)
Connector required: RJ21 Amphenol male plug
With some connectors it may not be possible to fully tighten the retaining screws. This can lead to loose connections. If this occurs it is recommended to replace the screws on the plug with 9.53m (3/8”) screws with a #4-40 thread. These can be sourced from many suppliers, for example Digikey.
Pin | Function |
|---|---|
1 | Tip1 |
2 | Tip2 |
…. | ….. |
23 | Tip23 |
24 | Tip24 |
25 | Tip25 |
26 | Ring1 |
27 | Ring2 |
28 | Ring3 |
…. | …. |
48 | Ring23 |
49 | Ring24 |
50 | Ring25 |
4x4 Analogue Ports
Connector required: RJ45 male plug
Pin | FXS | FXO | FWIC | Gen-Gen |
|---|---|---|---|---|
1 |
|
|
|
|
2 |
|
|
|
|
3 | Tip | Tip | Receive |
|
4 | Ring | Ring | Transmit | Transmit / Receive |
5 |
|
| Transmit | Transmit / Receive |
6 |
|
| Receive |
|
7 |
|
|
|
|
8 |
|
|
|
|
Digital BRI Ports (60G/60Gv2)
Connector required: RJ45 male plug
Pin | TE | NT |
|---|---|---|
1 |
|
|
2 |
|
|
3 | Transmit | Receive |
4 | Receive | Transmit |
5 | Receive | Transmit |
6 | Transmit | Receive |
7 |
|
|
8 |
|
|
Digital PRI Ports (100G/100Gv2/200G/200Gv2/400G/400Gv2)
Connector required: RJ45 male plug
On the 100G/100Gv2/200G/200Gv2 port 1 is wired as a CPE and port 2 is wired as an NT.
For the 400G and 400Gv2 the NT/TE configuration can be changed via software configuration.
Pin | TE | NT |
|---|---|---|
1 | Receive | Transmit |
2 | Receive | Transmit |
3 |
|
|
4 | Transmit | Receive |
5 | Transmit | Receive |
6 |
|
|
7 |
|
|
8 |
|
|