Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

IMG 1010 - Provisioning CICs

Provisioning CIC's is done from the Object Table in ClientView. From the Object Table Tab under the Circuit Group Configuration Pane select the cics to be provisioned. Once selected, right click and select from the drop down list the desired operation. Below is the Object Table from the different Software Versions.

The selections may vary depending on which software build being used.

You can select a group of CICs by dragging the cursor.

Software 10.3.x

Software 10.5.x

  • In Service - Bring a CIC into service from an Out of Service State

  • Out of Service - Take a CIC Out of Service

  • Maintenance Block - Initiate a Maintenance Block on a specific CIC or range of CIC's. Calls will not be processed on a CIC put into Maintenance Block Mode. Any calls that are on that circuit will be brought to an idle state gracefully. Any calls on that cic will be allowed to continue until call is released.

  • Maintenance Unblock - Unblock a CIC or range of CIC's from the Maintenance Block state

  • Reset - Reset a CIC.

  • Circuit Query Message - Send a CQM (Circuit Query Message) to query for the CIC state. The CQM and CQR (Circuit Query Request) is printed in the Call Tracing. Can query 1 CIC at a time. Cannot query a range of CICs

  • Continuity Check Request - Initiate a Continuity Test (COT Test). The result will appear in the Manual COT Test Results Column. Used for troubleshooting a circuit

  • Graceful Out Of Service - Bring CIC or range of CIC's Out of Service Gracefully. Allow any calls to be released before bringing CIC to an idle state

  • No labels