IMG 1010 - E1 CAS Timers

Timer ID

Description: (State Used); Timer Description

Default Value

1

(S19) Incoming Layer 4 busy out Acknowledge wait

4000

2

(S2) Incoming Stage 1 FWD digit receive wait

20000

3

(S3) Incoming Stage 2 FWD digit receive wait

20000

4

(S4) Incoming Stage 3 FWD digit receive wait

20000

5

(S5) Incoming Stage 4 FWD digit receive wait

20000

6

(S13) Layer 4 Connect wait

24,0000

7

(S14) Layer 4 wait

4000

8

(S21) Clear Forward (idle line signaling) wait

15000

9

(S3) Incoming Stage 2 Initial FWD digit receive wait

20000

10

(S2) Incoming Stage 1 Initial FWD digit receive wait

20000

11

(S5) Incoming Stage 4 Initial FWD digit receive wait

20000

12

(S4) Incoming Stage 3 Initial FWD digit receive wait 2000

20000

13

(S15) Layer 3 Circuit Release wait

100

14

(S18) Layer 3 Circuit Release wait

100

15

(S6) Host Control Wait

60000

16

(S13) Layer 3 Connect wait

240000

17

(S29) Seize Acknowledge wait

4000

18

(S31) Time to wait before transmitting idle signal after detecting glare

100

19

(S32) Time to wait before looking for idle signal after transmitting idle signal after detecting glare

100

20

(S39) Outgoing Stage 1 BWD R2 signal wait

15000

21

(S39) Outgoing Stage 1 Initial BWD R2 signal wait

15000

22

(S41) Outgoing Stage 2 BWD R2 signal wait

15000

23

(S41) Outgoing Stage 2 Initial BWD R2 signal wait

15000

24

(S43) Outgoing Stage 3 BWD R2 signal wait

15000

25

(S43) Outgoing Stage 3 Initial BWD R2 signal wait

15000

26

(S45) Outgoing Stage 4 BWD R2 signal wait

15000

27

(S45) Outgoing Stage 4 Initial BWD R2 signal wait

15000

28

(S46) Outgoing wait for answer

24000

29

(S48) Outgoing Layer 4 Clear wait

4000

30

(S49) Outgoing idle line signal wait

120000

31

(S50) Outgoing idle line signal wait after glare detected

120000

32

(S24) Host Control wait

240000

33

(S33) Time to wait for Clear Forward after glare detected

10000

34

Receive line signaling filter

40

36

(S6, S24) Incoming BWD R2 Cycle Complete Event wait

4000

38

(S10) Time to wait for idle line signaling after invalid line signal detected while receiving FWD R2 digits

20000

39

(S22) Layer 3 Clear Forward wait

3000

40

(S39) Outgoing Stage 1 BWD A signal wait after sending all of Stage 1 FWD digits

20000

41

(S2, S3, S4, S5) FWD R2 digits receive wait when String Collection Data field in Inpulsing Parameters Configure is set to 0xFF

200

43

R2 Cycle Complete Event wait

2000

45

(S43) Time to wait for next BWD R2 signal when stage 3 digits have been outpulsed

20000

  