IMG 1010 - Network Interfaces - Two Subnets Scenario 2
Scenario 3 - Two Subnets B: Data/Signaling and Control
In the following scenario, combine the signaling and data on one subnet and the control on another subnet. When configuring H.323 or SIP Signaling, select 10.10.30.70 for the IP Address in the IMG 1010 - H.323 Signaling Object or IMG 1010 - SIP Signaling Object.
Stream Type and Where Assigned | Sample IP Address | Physical Interface | Logical Interface | Port on Back Plane |
ControlAssigned at BootP | 10.10.25.2 | CPU | Redundant Control | CTRL 0 or 1 |
H.323 or SIP SignalingAssigned at Network Interfaces Pane | 10.10.30.70 | CPU (H.323/SIP) | Redundant Data | DATA 0 or 1 |
IP Bearer DataAssigned at Network Interfaces Pane | 10.10.30.100 | VoIP Module 0 | Redundant Data | DATA 1 or 0 |
IP Bearer DataAssigned at Network Interfaces Pane | 10.10.30.101 | VoIP Module 1 | Redundant Data | DATA 1 or 0 |