IMG 1010 - SS7 Features
Below is a list of ISUP variants the IMG supports.
|
|
|
|
|
|
|
|
|
|
|
|
Misc
IMG 1010 - FCI Override - Forward Call Indicators contain information relating to the characteristics of the connection, signaling path and called party sent in the forward direction. This is a mandatory parameter in IAM messages, which is used in countries that offer CUG (closed user group) service. Using the IMG 1010 - FCI Override pane, you can configure the IMG to send or ignore various indicators. See IMG 1010 - Configuring SS7 CIC Routing
Circuit Query Message - The Circuit Query Message (CQM) can be sent to a CIC or a group of CICs using the IMG 1010 - Circuit Group pane. The CIC status will update accordingly if there has been any change.
COT Test
Suppress UCICs - This feature allows you control the sending of UCIC. By default, UCIC is sent for National calls, and is suppressed for International calls, based on the Network Indicator setting of the SS7 Stack. You can change these setting if required in the IMG 1010 - SS7 Stack Pane.
Control CICs on up to 32 IMG's
Gain Control on SS7 Channel Groups
Interworking
ISDN to SIP, SS7 ISUP, and H.323
SS7 ISUP to SIP
SIP to SS7 ISUP Interworking: Calling Party Category