Before being able to configure ISDN Facility Tunneling in SIP INFO message feature, the following objects must first be configured:

Configure these initial objects before proceeding to the procedure below.

...

  • Right Click on the Profiles object and select New SIP SGP. Once SIP SGP pane is created, change the SIP Profile ID to something other than 0 by selecting a different ID from the drop down menu. This will allow user to edit the SIP SGP Profile. Refer to IMG 1010 - SIP Profile - 10.5.3 topic for more information on configuring this object.

  • Right Click on the SIP SGP object and select New SIP Headers. In the SIP Headers object that appears enable the X-Dialogic ISDN Data field. See screen capture below. Refer to IMG 1010 - SIP Headers topic for more information.

    Image RemovedImage Added

Create SIP Signaling Stack

...

Right click on the Signaling object and select New SIP. Refer IMG 1010 - SIP Signaling Object to the topic for more information on configuring this object. 

...

Right click on Channel Groups object and select New Channel Group. Set the Signaling Type field to SIP and enter a name for this channel group. Refer to IMG 1010 - Channel Group topic for more information on configuring a SIP Channel Group. 

...

  • Right click on IMG EMS and select New External Network Elements. No configuration is accomplished here. The External Network Element pane is a parent object to multiple external entities in the network. Refer to IMG 1010 - External Network Elements topic for more information.

  • Right click on the External Network Elements object and select New External Gateways. Again, no configuration is accomplished here. Refer to IMG 1010 - External Gateways object for more information.

  • Right click on External Gateways object and select New External Gateway. Enter a name to identify this gateway, modify the Gateway Signaling Protocol field to display SIP, and enter an IP address in the Gateway IP Address field.

  • Within the SIP Profile field select the SIP SGP created above for the X-Dialogic ISDN Data feature. See screen capture below. Refer to the IMG 1010 - External Gateway topic for more information.

    Image RemovedImage Added

Point SIP Channel group to gateway created

...

Right Click on the SIP Channel group created above and select New IP Network Element. In the IP Network Element field, select from drop down menu the gateway created above. Refer to the IMG 1010 - IP Network Element topic for more information on this object. See screen capture below

...