Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Configure M3UA Application Server Stack:

...

  • Right click on the IMG Name object in ClientView and select New Signaling. The Signaling Pane will appear. There is no configuration needed in this pane. This is a placeholder to be able to create SS7 signaling stacks. See IMG 1010 - Signaling Object for more information.

  • Right Click on the Signaling object and select New SS7. An SS7 signaling pane will appear. Select whether this configuration will be a standalone or Redundant system. In this example, standalone was selected. See IMG 1010 - SS7 Signaling Object

  • Right Click on the SS7 Signaling object created and select New SS7 Stack. An SS7 Stack 0 ClientView Pane will appear. Configure the following parameters to configure Stack 0 as an Application Server stack.

    • OPC - Click in the OPC field and an Enter Point Code box will appear. Enter the point code for Application Server Stack 0. In this example 0-0-7 was selected.

    • SCCP - Select ANSI if T1 or ITU if E1 from drop down menu

    • M3UA Service - Select Application Server (AS) Mode from drop down menu. 

...

See IMG 1010 - SS7 Stack for more information about configuring the rest of the Stack fields. (Non M3UA related)

...

  • Create the St-links. Right Click on the Remote SG object just created and select New Sigtran Link. A Sigtran Link ClientView Pane will appear as shown below. Fill in the fields as needed. See IMG 1010 - M3UA Sigtran Link for more information.

    • Primary/Secondary - Select whether the St-link will be a primary or secondary link.

    • Network Appearance - Since this is a standalone setup, the Network Appearance is not needed

    • Client/Server - Select whether the IMG will be server or client. In this example the default which is client was accepted.

    • Source Port - Enter the Port Number to be utilized. The default port for local and remote ST-Links is 2905.

    • Destination Port - Enter the port number of the remote Application Server that the St-link will be connecting to. The default port for local and remote ST-Links is 2905

    • Local IP 1 - Select which interface on the IMG that the M3UA signaling will be utilizing.

    • Remote IP 1 - Enter the IP address of the Remote Signaling Gateway Server interface that the St-link will be communicating with.

    • Local IP 2 - If there is a second interface which would be used for Redundancy select from drop down menu the IP address of the second interface.

    • Remote IP 2 - If redundancy is being configured, enter IP address of the remote application servers redundant IP interface

    • Comments - Enter a comment to identify this St-link 

...

  • Right Click on the Signaling Gateway Stack being configured and select New DPC Route. Information such as Route ID, Destination Point Code, and Remote SG need to be configured in this pane. See IMG 1010 - M3UA DPC Route and ClientView Pane below for more information.

    • M3UA DPC - Click in the M3UA DPC field and an "Enter DPC" box will appear. Enter the Destination Point Code of a separate Application Server stack that the stack being configured will be communicating with through IP. In this example Application Server Stack 0 which has a Point Code of 0-0-7 will be communicating with Application Stack 1 which has a point code of 0-0-8. Therefore 0-0-8 which is the remote Application Server stack is input into this field.

    • Remote SG - Click in the Remote SG field and a drop down menu displaying all the Remote Signaling Gateways created under the Application Server Stack. Select which Remote Signaling Gateway to communicate with.

    • Presume Available

      • False (Default) - When false is selected from drop down menu, it is assumed that all routes in the Remote Signaling Gateway are NOT available.

      • True - When True is selected from drop down menu it is assumed that all routes in the Remote Signaling Gateway are available.

...

  • Right Click on Dialogic IMG EMS object and select New Routing Configuration. See IMG 1010 - Routing Configuration Object for more information.

  • Right Click on Routing Configuration just created and select New Channel Groups. See IMG 1010 - Channel Groups for more information.

  • Right Click on the Channel Groups object and select New Channel Group. Enter a name for the Channel Group and select SS7 as the Signaling Type. See IMG 1010 - Channel Group for more information on configuring the SS7 Channel Group.

  • Right Click on the Channel Group just created and select New ISUP Group. In the OPC-DPC field will be a drop down menu with the two Application Servers created above. Select Application Server Stack 0 (OPC=0-0-7). See screen capture below.

...

  • Right Click on the ISUP Group and select New Circuits. Select the Spans/Channels to be used. See IMG 1010 - Circuit Group for more information

  • Create a second Channel Group, ISUP Group, and Circuits Pane. The ISUP Group will have the OPC-DPC field of the second Application Server stack (0-0-8) created above and the circuit groups of both Application Server stacks must be physically connected.

  • Once configured, the CIC's will come In Service. Verify this by viewing the 'Object Table' below the Circuits object pane in ClientView.

  • Below is a screen capture of the object tree in ClientView. Note that this procedure configures the Application Server Stacks on the same IMG 1010. The Application server stacks can also be created on separate IMG 1010's.

...

  • The IMG 1010 can connect a traditional SS7 stack to an External Signaling Gateway also. See IMG 1010 - SS7 Stack for information on configuring SS7 stack. In this situation, there must be a physical connection for the link between the IMG 1010 and the external Signaling Gateway. Also there must be physical links between CIC's on the IMG 1010 in the SS7 network and CIC's configured on the Application Server Stack. See Network Diagram above.

  • Below is screen capture of the ClientView object tree of a configured IMG 1010 connecting to IMG 1010 Application Server. Use diagram above for point codes etc. 

...