After creating the ISUP Profile object (ANSI or ITU), the profile created can then be linked to the ISUP Group (ANSI or ITU). The ISUP Profile is linked to the ISUP Group by selecting the ISUP Profile from a drop down menu in the ISUP Profile field within the ISUP Group object.

Profiles

SS7 - ISUP Profile - ANSI

Field Descriptions

Profile Name

...


Reject Calls (Default) - If IMG 2020 receives a call with the CUG parameters (Interlock Codes) it will reject the call with a cause code of 29 facility rejected. See Call Trace - CUG rejected which is call trace of rejected call with CUG parameter.

Ignore - If IMG 2020 receives a call with the CUG parameters (Interlock Codes) it will pass the call. See Call Trace - CUG passed which is a call trace of a passed call with CUG parameter.

...