IMG 2020

On rear panel of the IMG 2020 there are three DS-3 Interfaces. Before configuring the TDM DS-1 objects, each individual DS-3 interface needs to be configured. Depending on whether the IMG 2020 is configured will depend on the number of DS-1's/DS-0's that can be configured. Both T1 DS-3 and E1 DS-3 are supported. To configure, right click on the DS3/Optical Mode object and select New DS-3 Interface. This will create the TDM DS-3 Interface object. Once the DS3 Interface object is created the individual DS1 Spans will need to be configured. Refer to information below.

...

After configuring the DS-3 Interfaces on rear of IMG 2020, each individual TDM DS-1/DS-0 must then be configured. See TDM Span (DS3) topic.

DS3 - Optical Mode

DS-1 Spans

Configure Facilities 

Field Descriptions

Interface ID

...