Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

FR 19810 Baudot tone detection and TTY call flow support.

Brief Description:

IMG 2020 is now able to detect Baudot tone and generate an outgoing SIP INVITE with tty-ind SIP URI parameter upon detection. 

Related Topics:

IP Profiles

SIP Profile - Advanced Settings

F-1376 Edit a Channel Group label after the group has been saved.

Brief Description:

IMG 2020 now allows the modification of the Channel Group label. 

Related Topics:

Channel Group

F-1377 Span description on the DS1 Spans Facility Object.

Brief Description:

IMG 2020 now supports an editable span name. 

Related Topics:

Span Status Monitoring

F-1379 Add SS7 COT results status in Channel Group grid.

Brief Description:

IMG 2020 now displays the latest manual COT result in the SS7 monitoring fields. 

Related Topics:

SS7 - CIC

F-1383 Display SIP Options Keep Alive status in WebUI.

Brief Description:

IMG 2020 now displays the External Gateway  SIP Options Keep Alive Status.

Related Topics:

External Gateway

F-1386 Additional settings on the A-F digits used in outgoing SIP calls.

Brief Description:

IMG 2020 now gives the possibility to output the hexadecimal digits in upper case.

Related Topics:

SIP Profile - Advanced Settings

F-1387 Diversion header parameter injection of outgoing SIP call.

Brief Description:

IMG 2020 now gives the possibility to add a configurable diversion header to SIP outgoing call.

Related Topics:

SIP Profile-Diversion Header

  • No labels