IMG 1010 - Network Interfaces - Two Subnets Scenario 2

Scenario 3 - Two Subnets B: Data/Signaling and Control

In the following scenario, combine the signaling and data on one subnet and the control on another subnet. When configuring H.323 or SIP Signaling, select 10.10.30.70 for the IP Address in the IMG 1010 - H.323 Signaling Object or IMG 1010 - SIP Signaling Object.

Stream Type and Where Assigned

Sample IP Address

Physical Interface

Logical Interface

Port on Back Plane

ControlAssigned at BootP

10.10.25.2

CPU

Redundant Control

CTRL 0 or 1

H.323 or SIP SignalingAssigned at Network Interfaces Pane

10.10.30.70

CPU (H.323/SIP)

Redundant Data

DATA 0 or 1

IP Bearer DataAssigned at Network Interfaces Pane

10.10.30.100

VoIP Module 0

Redundant Data

DATA 1 or 0

IP Bearer DataAssigned at Network Interfaces Pane

10.10.30.101

VoIP Module 1

Redundant Data

DATA 1 or 0

ClientView Panes: