Licensing (Gateway Mode)

The IMG 2020 can have Gateway functionality, Session Border Controller Functionality, or both. Using the IMG 2020 specifically as a Gateway requires a license to open various functions including SS7 Signaling, ISDN Signaling, and VoIP. The licenses are distributed by email when the product is purchased. Each license will unlock a different function and the licenses are sold in multiple increments to address each customer needs. After receiving the license, transfer the license using SFTP to the SD card or FTP server (whichever the system software file is loaded from). Click on the Physical Node IMG 2020 object. In the object page, click on the Download New License button. The license will automatically download to the IMG 2020 node.

The license file needs to be loaded into the directory that the system software binary file is loaded. If using SD Card, load license file onto the SD Card if loading through FTP server, the license must be loaded in the directory that the system software file is loaded.

File Format

The license file supplied contains a unique number which is derived from the serial number of the I/O board located on a white sticker near the power supplies on the rear of the IMG 2020 and a 12 bit unique number embedded in the hardware. The format of the file includes an eight digit serial number (NNNNNNNN) followed by a timestamp (YYYYMMDDhhmmss). If the license is renamed or altered, it will become unusable. Refer to the example below.

License Naming Convention -NNNNNNNN_YYYYMMDDhhmmss.cfg 

Downloading the license

When downloading a license file to the IMG 2020, the download utility looks for a file whose name includes the serial number of the IMG 2020. Therefore when downloading a new license file, the old license should either be removed or modified to not contain the serial number, so when the download utility looks for the serial number it won't find the old license. For example, if the old license file was 10311234_20180101130221.cfg then the old license should either be removed from the directory or renamed to something like xx311234_20180101130221.cfg

  • On the SD Card or FTP server, remove or rename any existing licenses (Refer to paragraph above). Using an SFTP application, transfer the updated license file to either the SD card or the FTP server. Refer to the SFTP Server topic for information on transferring. It is recommended to use the original file name for the current license, but it can be renamed as long as it includes the IMG serial number and has the extension .cfg (and doesn't include more than one ".", compound extensions like ".new.cfg" are not supported).

  • Create the License Info object by right clicking on the Physical Node object and selecting New Licensing Info. Within the License Info page, make note of the current licensing since this will be updated after the license download. Refer to the License Info topic for more information on this object.

  • Within the Web GUI, click on the Physical Node IMG 2020 object in the object tree.

  • Click on the Download New License button at the bottom of the License Info object pane. The license loaded will be sent to the IMG 2020.

  • After license is sent, refresh the Web GUI page. Click on the License Info object and verify the new license has been loaded.

The license is downloaded based on the serial number and a unique number embedded in the hardware. If a license other than the license intended for this node is sent, the license will not download. The license being sent has to be specifically created for this nodes serial number and unique number. If license is renamed or in any way altered, it will become unusable.

Viewing License Information

Use the License Info page to view page status

Evaluation License

Evaluation licenses expire after a specified number of days. The License Expiration field within the License Info pane indicates the date and time the evaluation license expires. Licenses that are not designated as evaluation licenses will display Does Not Expire. Seventy-two hours before an evaluation license is set to expire, an EventView alarm displays the number of hours remaining on the evaluation license.

License Validation Failure

The following icon below is displayed in front of the IMG 2020 object if the license does not validate with the node it was sent to.

A license validation has failed. Verify the serial number for license is serial number of IMG 2020. Refer to the License Info topic

Licensed Components

Below is a list of licenses that can be created. Information on each is provided in the table below.

If licensing remote CIC's, each remote node must have an SS7_ISUP port license that equals the number of CIC's being configured on that remote node.

If configuring SS7 Redundancy, both the Active node and its Peer/Redundant node must have an SS7 Base license.

License

Description

License Expiration Info(Optional)

Licenses generated for the IMG 2020 do not expire unless the license is specifically generated as an evaluation license. If the license is an evaluation license then the Date and Time the license expires is displayed in the License Expiration field of the License Info pane. If the license loaded is NOT an evaluation license then the License Expiration field will display Does Not Expire.  

Licenses do not expire unless the license is configured as an evaluation license.

SYSTEM_SOFTWARE

System Software License is needed on all IMG 2020 nodes and is specific to the software build.

SECURITY_ID

The security ID is a code embedded in the ROM of the IMG 2020 node. Each license generated must have the code embedded in the license file for the system to work.

SS7_BASE

Must be included in license file if SS7 stacks are going to be configured and used.

SS7_TCAP_TRANSACTION

Up to 2500 TCAP transactions/second in 100 transactions/second increments can be licensed.

SS7_LINK

Links are licensed in 2 link pairs, up to 64 links.

SS7_ISUP_PORT (CIC's)

Up to 2016 CIC's can be licensed.

SS7_M3UA_APP_SERVER_STACK

Up to four M3UA Application Server stacks can be licensed per IMG 2020 node. Licenses are created in one stack increments.

SS7_M3UA_SIG_GATEWAY_STACK

Up to four M3UA Signaling Gateway stacks can be licensed per IMG 2020 node. Licenses are created in one stack increments.

SS7_M3UA_SIGTRAN_LINK

Up to 64 associations can be licensed. Licenses are created in 2 step increments.

ISDN_PORT

Up to 2016 ports can be licensed for ISDN B channels. See table below.

TDM_PORT

There are a total of 2016 TDM ports available to be licensed. When initially purchasing the product, the licenses are sold as 1 DS3, 2 DS3's, or 3 DS3's. Once the initial license bundles are created, the TDM ports can then be licensed in subsequent 32 DS-0 increments. The table below displays the increments that the licenses are created in.  

If required, an additional 128 TDM Port licenses can be purchased and added making the total number of TDM ports 2144. Adding the extra TDM ports allows SS7 signaling links to be added to the four DS-1 interfaces located on the rear of the system.

VOIP_PORT

There are a total of 2016 VoIP Ports. The Maximum number of VoIP ports that can be licensed is 2016.  

The IMG 2020 has a maximum IP Port density of 2016 VoIP ports. This is true for all codecs except the AMR-NB and AMR-WB codecs.

AMR_CODEC (GW)_32 (NB)

The maximum number of VoIP ports using AMR-NB with two installed DSP modules is 1536. The maximum number of VoIP ports using AMR-NB with three installed DSP modules is 2016.

AMR_CODEC_WB (Wide Band)

The maximum number of VoIP ports using AMR-WB (G.722.2 RFC 3267) with two installed DSP modules is 768. The maximum number of VoIP ports using AMR-WB (G.722.2 RFC 3267) with three installed DSP modules is 1088. The maximum number of VoIP ports using AMR-WB (G.722.2 RFC 3267) with four installed DSP modules is 1376.

VIDEO_TRANSCODING

The maximum number of Video Transcoding licenses is 864. It takes 2 video transcoding licenses to achieve an end to end video call with transcoding functionality.

To make a video call without changing codecs (no transcoding), no licenses are required. Video calls do not need a license unless transcoding is to be applied.

AUDIO_TRANSCODING

The maximum number of Audio Transcoding licenses is 2016. It takes 2 audio transcoding licenses to achieve an end to end audio call with transcoding functionality.

To make a audio call without changing codecs (no transcoding), no licenses are required. Audio calls do not need a license unless transcoding is to be applied.

DSP_RESOURCE_POINT

All IMG 2020's comes fully licensed with 6144 DSP Resource Points.

SECURE_COMMUNICATIONS

The secure communication license adds the licensing needed to configure TLS. Once TLS is configured, SRTP can then be configured.

SYSTEM_SOFTWARE

System Software License is needed on all IMG 2020 nodes and is specific to the software build.

AUDIO_TRANSCODING

Maximum is Transcoding RTP

License Increments

The table below displays the increments in which licenses are generated. The IMG 2020 can have Gateway functionality, Session Border Controller Functionality, or both. The functionality is determined through licensing. The table below displays the increments in which the IMG 2020 with Gateway Functionality (Any Protocol to Any Protocol) are generated. Refer to Sangoma Sales and Support to determine which functionality would meet your needs.

License Scheme - Gateway

When purchasing a new unit, the minimum number of DS0's that can be purchased is One DS3 Bundle + 96 (4-RJ48 interfaces) = 768

TDM DS0's

SS7 ISUP Ports

ISDN

VoIP Ports

EVRC

AMR-NB

AMR-WB

(768 DS0's) Bundle 1

768

768

32

32

32

32

800

800

800

64

64

64

64

832

832

832

96

96

96

96

864

864

864

128

128

128

128

896

896

896

160

160

160

160*

928

928

928

192

192

192

192*

960

960

960

224

224

224

224*

896

896

896

256

256

256

256*

928

928

928

288

288

288

288*

960

960

960

320

320

320*

320*

992

992

992

352

352

352*

352*

1024

1024

1024

384

384

384*

384*

1056

1056

1056

416

416

416*

416*

1088

1088

1088

448

448

448*

448*

1120

1120

1120

480

480

480*

480**

1152

1152

1152

512

512

512*

512**

1184

1184

1184

544

544

544*

544**

1216

1216

1216

576

576

576*

576**

1248

1248

1248

608

608

608*

608**

1280

1280

1280

640

640

640*

640**

1312

1312

1312

672

672

672*

672**

1344

1344

1344

704

704

704*

704**

1376

1376

1376

736

736

736*

736**

1408

1408

1408

768

768

768*

768**

1440 (DS0's) Bundle 2

1440

1440

800

800

800*

800***

1472

1472

1472

832

832

832*

832***

1504

1504

1504

864

864

864*

864***

1536

1536

1536

896

896

896*

896***

1568

1568

1568

928

928

928*

928***

1600

1600

1600

960

960

960**

960***

1632

1632

1632

992

992

992**

992***

1664

1664

1664

1024

1024

1024**

1024***

1696

1696

1696

1056

1056

1056**

1056***

1728

1728

1728

1088

1088

1088**

1088***

1760

1760

1760

1120

1120

1120**

1120**

1792

1792

1792

1152

1152

1152**

1152**

1824

1824

1824

1184

1184

1184**

1184**

1856

1856

1856

1216

1216

1216**

1216**

1888

1888

1888

1248

1248

1248**

1248**

1920

1920

1920

1280

1280

1280**

1280**

1952

1952

1952

1312

1312

1312**

1312**

1984

1984

1984

1344

1344

1344**

1344**

2016 (DS0's) Bundle 3

2016

2016

1376

1376

1376**

1376**

2048

 

 

1408

1408

1408**

 

2080

 

 

1440

1440

1440**

 

2112

 

 

1472

1472

1472**

 

2144

 

 

1504

1504

1504**

 

 

 

 

1536

1536

1536**

 

 

 

 

1568

1568

1568***

 

 

 

 

1600

1600

1600***

 

 

 

 

1632

1632

1632***

 

 

 

 

1664

1664

1664***

 

 

 

 

1696

1696

1696***

 

 

 

 

1728

1728

1728***

 

 

 

 

1760

1760

1760***

 

 

 

 

1792

1792

1792***

 

 

 

 

1824

1824

1824***

 

 

 

 

1856

1856

1856***

 

 

 

 

1888

1888

1888***

 

 

 

 

1920

1920

1920***

 

 

 

 

1952

1952

1952***

 

 

 

 

1984

1984

1984***

 

 

 

 

2016

2016

2016***

 

In the table above, the number of asterisks equals the number of DSP modules required to meet the densities displayed.

  • Requires on board plus one DSP Modules.

** Requires two modules plus the on board DSP's

*** Requires three modules plus the on board DSP's

**** Requires four modules plus the on board DSP's