Scenario 1 - One Subnet IMG 1004
In this scenario all traffic runs over one subnet. The IP address of the interface labeled CTRL is configured automatically during the BootP process. When configuring H.323 or SIP Signaling, select 10.10.25.2 for the IP Address in the H.323 Signaling or SIP Signaling pane.
Stream Type and Where Assigned | Sample IP Address | Physical Interface | Logical Interface | Port on Back Plane |
Control: Assigned at BootP | 10.10.25.2 | CPU/CPU H.323/SIP | CTRL | CTRL |
Data: Assigned in Network Interface Pane | 10.10.25.100 | VoIP Module 0 | Data | Data |