The FAXStation CPE connects to your network by way of a single RJ45 ethernet cable. By default, the CPE units will get network parameters via DHCP. Static IPs may be set via various methods including the device web GUI, or by telephone feature code. Reference available at Feature Codes

 

Throughput requirements are minimal. The CPE device does periodically check in for provisioning (5 minutes) and new faxes (1 minute). Also, there is some minor keepalive traffic for the management platform. No specific bandwidth or throughput requirements exist, nor do any considerations need to be made for QoS or traffic prioritization for proper operation.

 

The CPE will need to have egress network access to the Sangoma FAXStation platform via the following:

Protocol

Port

Name

Network

Description

TCP

443

HTTPS

Sangoma

CPE uses HTTPS to talk with platform for all fax TX/RX as well as provisioning

UDP

4332-4339

N/A

Sangoma

CPE connects to platform for remote management/diagnostics/firmware

UDP

123

NTP

Public

CPE contacts us.pool.ntp.org for network time protocol if local RTC is not available or skew is too high

UDP

53

DNS

N/A

CPE uses DNS for hostname resolution, DNS servers provided by connected network DHCP server, or as specified in manual network configuration

 

Note, no port forwarding, NAT configuration, etc is required for FAXStation CPE to operate. The above listed ports need to be allowed egress (outbound) access by the CPE (with stateful return traffic allowed).

 