Dialogic IMG - IMG 1010 - Filter/Timer Configure
Description:
Use this pane to adjust CAS trunk and line signaling filters and timers. Typically this is only required when the trunk or line that the IMG is connected to is not operating to line interface specifications. All timers and filters are set to default values based on industry specifications when the channel trunk type is configured.
Accessing this Pane:
Dialogic IMG EMS -> Signaling -> <Variant Name> -> Filter/Timer Configure
Maximum Objects:
No Limit
Previous Configuration Required:
Related Topics:
Filter / Timer Pane (T1): (E1 shown below)
Field Descriptions:
PPL Filter/Timer Type:
In CAS the only selection is Generic Protocol Timer.
PPL Filter/Timer Selection (T1):
Below is a table which displays the Filter Timer Type along with the PPL number and selections for reference.
PPL Filter Type | PPL Filter/Timer Number | PPL Filter/Timer Selection | E&M | FXS Loopstart |
Generic Protocol Timer | 0x01 | Preseize | 10 |
|
| 0x02 | Inseize | 15 | 20 |
| 0x03 | Modified Incoming Release | 70 | 70 |
| 0x04 | Modified Outgoing Release | 70 | 70 |
| 0x05 | Normal Incoming Release | 70 | 70 |
| 0x06 | Normal Incoming Release with Flash | 102 | 102 |
| 0x07 | Normal Outgoing Release | 70 | 60 |
| 0x08 | Normal Outgoing Release with Flash | 102 | 102 |
| 0x09 | Post Inseize Acknowledgement |
|
|
| 0x0a | Outseize Acknowledgement | 10 | 10 |
| 0x0b | Outseize Answer | 35 |
|
| 0x0c | Outseize Dial Signal End | 4 |
|
| 0x0d | First Release | 70 | 15 |
| 0xe | ANI Request Off-Hook | 20 |
|
| 0x15 | Inseize Complete |
|
|
| 0x16 | Post Inseize Complete |
|
|
| 0x17 | Start Normal Outgoing Release | 0 |
|
| 0x18 | Start Normal Incoming Release | 0 |
|
| 0x19 | Outseize Acknowledgement | 500 | 64,0000 |
| 0x1a | Outseize Answer | 10,000 |
|
| 0x1b | Guard Timeout | 70 | 32,000 |
| 0x1c | Release | 32,000 |
|
| 0x1d | Glare Detection | 10 | 30 |
| 0x1e | Minimum Flash | 30 | 100 |
| 0x1f | Maximum Flash | 100 |
|
| 0x20 | Start Dial Minimum Wink | 10 |
|
| 0x21 | Start Dial Maximum Wink | 35 |
|
| 0x22 | Minimum Delay Dial Signal | 14 |
|
| 0x23 | Maximum Delay Dial Signal | 400 |
|
| 0x24 | Post Start Dial Signal Outpulse Delay | 8 |
|
| 0x25 | Wink 2 Minimum Receive Duration | 10 |
|
| 0x26 | Wink 2 Maximum Receive Duration | 50 |
|
| 0x27 | Wink 2 Minimum Post Outpulse Delay | 10 |
|
| 0x28 | Wink 2 Maximum Post Outpulse Delay | 350 |
|
| 0x29 | Wink 2 Maximum Receive Detection | 1,150 |
|
| 0x2a | Wink 3 Minimum Receive Duration | 10 |
|
| 0x2b | Wink 3 Maximum Receive Duration | 60 |
|
| 0x2c | Wink 3 Minimum Post Outpulse Delay | 10 |
|
| 0x2d | Wink 3 Maximum Post Outpulse Delay | 350 |
|
| 0x2e | Wink 3 Maximum Receive Duration | 400 |
|
| 0x2f | Wink 4 Minimum Receive Duration | 10 |
|
| 0x30 | Wink 4 Maximum Receive Duration | 35 |
|
| 0x31 | Wink 4 Minimum Post Outpulse Delay | 10 |
|
| 0x32 | Wink 4 Maximum Post Outpulse Delay | 350 |
|
| 0x33 | Wink 4 Maximum Receive Detection | 400 |
|
| 0x34 | Wink 5 Minimum Receive Duration | 10 |
|
| 0x35 | Wink 5 Maximum Receive Duration | 35 |
|
| 0x36 | Wink 5 Minimum Post Outpulse Delay | 10 |
|
| 0x37 | Wink 5 Maximum Post Outpulse Delay | 350 |
|
| 0x38 | Wink 5 Maximum Receive Detection | 400 |
|
| 0x39 | Wink 6 Minimum Receive Duration | 10 |
|
| 0x3a | Wink 6 Maximum Receive Duration | 35 |
|
| 0x3b | Wink 6 Minimum Post Outpulse Delay | 10 |
|
| 0x3c | Wink 6 Maximum Post Outpulse Delay | 350 |
|
| 0x3d | Wink 6 Maximum Receive Duration | 400 |
|
| 0x3e | Wink 7 Minimum Receive Duration | 10 |
|
| 0x3f | Wink 7 Maximum Receive Duration | 35 |
|
| 0x40 | Wink 7 Minimum Post Outpulse Delay | 10 |
|
| 0x41 | Wink 7 Maximum Pulse Outpulse Delay | 350 |
|
| 0x42 | Wink 7 Maximum Receive Detection | 400 |
|
| 0x43 | Wink 8 Minimum Receive Duration | 10 |
|
| 0x44 | Wink 8 Maximum Receive Duration | 35 |
|
| 0x45 | Wink 8 Minimum Post Outpulse Delay | 10 |
|
| 0x46 | Wink 8 Maximum Post Outpulse Delay | 350 |
|
| 0x47 | Wink 8 Maximum Receive Detection | 400 |
|
| 0x48 | Post ANI Off Hook Outpulse Delay | 100 |
|
| 0x49 | Maximum Receive ANI Off Hook Request Detection | 1600 |
|
| 0x4a | Maximum Receive Dial Tone Detection | 800 | 800 |
| 0x4b | MFR1 Minimum Receive KP Duration | 5 | 5 |
| 0x4c | MFR1 Minimum Receive Digit Duration | 3 | 3 |
| 0x4d | MFR1 Maximum Receive KP Duration | 1000 | 1000 |
| 0x4e | MFR1 Minimum Receive Inter-Digit Duration | 3 | 3 |
| 0x4f | MFR1 Maximum Receive Inter-Digit Duration | 1000 | 1000 |
| 0x50 | DTMF Maximum Receive 1st Digit Detection | 2000 | 2000 |
| 0x51 | DTMF Minimum Receive Digit Duration | 4 | 4 |
| 0x52 | DTMF Minimum Receive Inter-Digit Duration | 4 | 4 |
| 0x53 | DTMF Maximum Receive Inter-Digit Duration | 2000 | 2000 |
| 0x5b | Wink Duration | 20 |
|
| 0x5c | Flash Duration | 60 | 60 |
| 0x5d | Primary Outseize Signal |
|
|
| 0x5e | Outseize Signaling Complete | 30 |
|
| 0x5f | Delay Dial Signal Start | 7 |
|
| 0x60 | Fixed Pause | 7 |
|
| 0x61 | Timed Answer |
|
|
| 0x62 | Ringing ON Duration |
| 200 |
| 0x63 | Ringing OFF Duration |
| 400 |
| 0x64 | Wink 1 Minimum Transmit Delay | 8 |
|
| 0x65 | Wink 2 Minimum Transmit Delay | 30 |
|