IMG 1010 - Filter/Timer Configure

Description:

Use this pane to adjust CAS trunk and line signaling filters and timers. Typically this is only required when the trunk or line that the IMG is connected to is not operating to line interface specifications. All timers and filters are set to default values based on industry specifications when the channel trunk type is configured.

Accessing this Pane:

Dialogic IMG EMS -> Signaling -> <Variant Name> -> Filter/Timer Configure

Maximum Objects:

No Limit

Previous Configuration Required:

IMG 1010 - Signaling Variant

Related Topics:

IMG 1010 - Configuring CAS 

Filter / Timer Pane (T1): (E1 shown below)

Field Descriptions:

PPL Filter/Timer Type:

In CAS the only selection is Generic Protocol Timer.

PPL Filter/Timer Selection (T1):

Below is a table which displays the Filter Timer Type along with the PPL number and selections for reference.

PPL Filter Type

PPL Filter/Timer Number

PPL Filter/Timer Selection

E&M

FXS Loopstart

Generic Protocol Timer

0x01

Preseize

10

 

 

0x02

Inseize

15

20

 

0x03

Modified Incoming Release

70

70

 

0x04

Modified Outgoing Release

70

70

 

0x05

Normal Incoming Release

70

70

 

0x06

Normal Incoming Release with Flash

102

102

 

0x07

Normal Outgoing Release

70

60

 

0x08

Normal Outgoing Release with Flash

102

102

 

0x09

Post Inseize Acknowledgement

 

 

 

0x0a

Outseize Acknowledgement

10

10

 

0x0b

Outseize Answer

35

 

 

0x0c

Outseize Dial Signal End

4

 

 

0x0d

First Release

70

15

 

0xe

ANI Request Off-Hook

20

 

 

0x15

Inseize Complete

 

 

 

0x16

Post Inseize Complete

 

 

 

0x17

Start Normal Outgoing Release

0

 

 

0x18

Start Normal Incoming Release

0

 

 

0x19

Outseize Acknowledgement

500

64,0000

 

0x1a

Outseize Answer

10,000

 

 

0x1b

Guard Timeout

70

32,000

 

0x1c

Release

32,000

 

 

0x1d

Glare Detection

10

30

 

0x1e

Minimum Flash

30

100

 

0x1f

Maximum Flash

100

 

 

0x20

Start Dial Minimum Wink

10

 

 

0x21

Start Dial Maximum Wink

35

 

 

0x22

Minimum Delay Dial Signal

14

 

 

0x23

Maximum Delay Dial Signal

400

 

 

0x24

Post Start Dial Signal Outpulse Delay

8

 

 

0x25

Wink 2 Minimum Receive Duration

10

 

 

0x26

Wink 2 Maximum Receive Duration

50

 

 

0x27

Wink 2 Minimum Post Outpulse Delay

10

 

 

0x28

Wink 2 Maximum Post Outpulse Delay

350

 

 

0x29

Wink 2 Maximum Receive Detection

1,150

 

 

0x2a

Wink 3 Minimum Receive Duration

10

 

 

0x2b

Wink 3 Maximum Receive Duration

60

 

 

0x2c

Wink 3 Minimum Post Outpulse Delay

10

 

 

0x2d

Wink 3 Maximum Post Outpulse Delay

350

 

 

0x2e

Wink 3 Maximum Receive Duration

400

 

 

0x2f

Wink 4 Minimum Receive Duration

10

 

 

0x30

Wink 4 Maximum Receive Duration

35

 

 

0x31

Wink 4 Minimum Post Outpulse Delay

10

 

 

0x32

Wink 4 Maximum Post Outpulse Delay

350

 

 

0x33

Wink 4 Maximum Receive Detection

400

 

 

0x34

Wink 5 Minimum Receive Duration

10

 

 

0x35

Wink 5 Maximum Receive Duration

35

 

 

0x36

Wink 5 Minimum Post Outpulse Delay

10

 

 

0x37

Wink 5 Maximum Post Outpulse Delay

350

 

 

0x38

Wink 5 Maximum Receive Detection

400

 

 

0x39

Wink 6 Minimum Receive Duration

10

 

 

0x3a

Wink 6 Maximum Receive Duration

35

 

 

0x3b

Wink 6 Minimum Post Outpulse Delay

10

 

 

0x3c

Wink 6 Maximum Post Outpulse Delay

350

 

 

0x3d

Wink 6 Maximum Receive Duration

400

 

 

0x3e

Wink 7 Minimum Receive Duration

10

 

 

0x3f

Wink 7 Maximum Receive Duration

35

 

 

0x40

Wink 7 Minimum Post Outpulse Delay

10

 

 

0x41

Wink 7 Maximum Pulse Outpulse Delay

350

 

 

0x42

Wink 7 Maximum Receive Detection

400

 

 

0x43

Wink 8 Minimum Receive Duration

10

 

 

0x44

Wink 8 Maximum Receive Duration

35

 

 

0x45

Wink 8 Minimum Post Outpulse Delay

10

 

 

0x46

Wink 8 Maximum Post Outpulse Delay

350

 

 

0x47

Wink 8 Maximum Receive Detection

400

 

 

0x48

Post ANI Off Hook Outpulse Delay

100

 

 

0x49

Maximum Receive ANI Off Hook Request Detection

1600

 

 

0x4a

Maximum Receive Dial Tone Detection

800

800

 

0x4b

MFR1 Minimum Receive KP Duration

5

5

 

0x4c

MFR1 Minimum Receive Digit Duration

3

3

 

0x4d

MFR1 Maximum Receive KP Duration

1000

1000

 

0x4e

MFR1 Minimum Receive Inter-Digit Duration

3

3

 

0x4f

MFR1 Maximum Receive Inter-Digit Duration

1000

1000

 

0x50

DTMF Maximum Receive 1st Digit Detection

2000

2000

 

0x51

DTMF Minimum Receive Digit Duration

4

4

 

0x52

DTMF Minimum Receive Inter-Digit Duration

4

4

 

0x53

DTMF Maximum Receive Inter-Digit Duration

2000

2000

 

0x5b

Wink Duration

20

 

 

0x5c

Flash Duration

60

60

 

0x5d

Primary Outseize Signal

 

 

 

0x5e

Outseize Signaling Complete

30

 

 

0x5f

Delay Dial Signal Start

7

 

 

0x60

Fixed Pause

7

 

 

0x61

Timed Answer

 

 

 

0x62

Ringing ON Duration

 

200

 

0x63

Ringing OFF Duration

 

400

 

0x64

Wink 1 Minimum Transmit Delay

8

 

 

0x65

Wink 2 Minimum Transmit Delay

30

 

 

0x66

Wink 2 Maximum Transmit Delay

1150

 

 

0x67

Wink 2 Transmit Duration

20

 

 

0x68

Wink 3 Minimum Transmit Delay

10

 

 

0x69

Wink 3 Maximum Transmit Delay

40

 

 

0x6a

Wink 3 Transmit Duration

20

 

 

0x6b

Wink 4 Minimum Transmit Delay

8

 

 

0x6c

Wink 4 Maximum Transmit Delay

40

 

 

0x6d

Wink 4 Transmit Duration

20

 

 

0x6e

Wink 5 Minimum Transmit Delay

8

 

 

0x6f

Wink 5 Maximum Transmit Delay

40

 

 

0x70

Wink 5 Transmit Duration

20

 

 

0x71

Wink 6 Minimum Transmit Delay

8

 

 

0x72

Wink 6 Maximum Transmit Delay

40

 

 

0x73

Wink 6 Transmit Duration

20

 

 

0x74

Wink 7 Minimum Transmit Delay

8

 

 

0x75

Wink 7 Maximum Transmit Delay

40

 

 

0x76

Wink 7 Transmit Duration

20

 

 

0x77

Wink 8 Minimum Transmit Delay

8

 

 

0x78

Wink 8 Maximum Transmit Delay

40

 

 

0x79

Wink 8 Transmit Duration

20

 

 

0x7a

MFR1 Transmit KP Duration

10

10

 

0x7b

MFR1 Transmit Digit Duration

6

6

 

0x7c

MFR1 Transmit Inter-Digit Duration

6

6

 

0x7d

DTMF Transmit Digit Duration

6

6

 

0x7e

DTMF MFR1 Transmit Inter-Digit Duration

6

6

PPL Filter/Timer Value.

Each PPL Filter/Timer Selection can be modified. Click in the PPL Filter/Timer Value field and the following popup will appear. Enter a value which will be in milliseconds

Filter / Timer Pane (E1):

PPL Filter/Timer Type:

Select from a drop down menu one of the following:

Generic Protocol Timer

R2 Signaling Timer

DTMF Signaling Timer

MFR1 Signaling Timer


PPL Filter/Timer Selection (E1):

Below is a table which displays the Filter Timer Type along with the PPL number and selections for reference.

PPL Filter Type

PPL Filter/Timer Number

PPL Filter/Timer Selection

Value (ms)

Generic Protocol Timer

0x01

Incoming Layer 4 Busy Out Acknowledge Wait

400

 

0x02

Incoming Stage 1 Fwd digit receive wait

2000

 

0x03

Incoming Stage 2 Fwd digit receive wait

2000

 

0x04

Incoming Stage 3 Fwd digit receive wait

2000

 

0x05

Incoming Stage 4 Fwd digit receive wait

2000

 

0x06

Layer 4 Connect Wait

24,000

 

0x07

Layer 4 Wait

400

 

0x08

Clear Forward

1500

 

0x09

Incoming Stage 2 Initial Fwd digit receive wait

2000

 

0x0a

Incoming Stage 1 Initial Fwd digit receive wait

2000

 

0x0b

Incoming Stage 4 Initial Fwd digit receive wait

2000

 

0x0c

Incoming Stage 3 Initial Fwd digit receive wait

2000

 

0x0d

Layer 3 Circuit Release Wait

10

 

0xe

Layer 3 Circuit Release Wait

10

 

0x0f

Host Control Wait

6000

 

0x10

Layer 3 Connect Wait

24,000

 

0x11

Seize Acknowledge Wait

400

 

0x12

Wait to transmit after receiving Glare

10

 

0x13

Wait to look for transmitted idle after detecting glare

10

 

0x14

Outgoing Stage 1 BWD R2 signal wait

1500

 

0x15

Outgoing Stage 1 Initial BWD R2 signal wait

1500

 

0x16

Outgoing Stage 2 BWD R2 signal wait

1500

 

0x17

Outgoing Stage 2 Initial BWD R2 signal wait

1500

 

0x18

Outgoing Stage 3 BWD R2 signal wait

1500

 

0x19

Outgoing Stage 3 Initial BWD R2 signal wait

1500

 

0x1a

Outgoing Stage 4 BWD R2 signal wait

1500

 

0x1b

Outgoing Stage 4 Initial BWD R2 signal wait

1500

 

0x1c

Outgoing wait for answer

24,000

 

0x1d

Outgoing Layer 4 clear wait

400

 

0x1e

Outgoing Idle line signal wait

12,000

 

0x1f

Outgoing Idle line signal wait after glare detected

12,000

 

0x20

Host Control Wait

24,000

 

0x21

Wait for clear wait after glare detected

1000

 

0x22

Receive Line signaling filter

4

 

0x24

Incoming BWD R2 cycle complete event wait

400

 

0x26

Wait for idle after invalid line signal during FWD R2 digit

2000

 

0x27

Layer 3 Clear Forward

300

 

0x28

Wait after stage 1 FWD digits Outgoing Stage 1 BWD A

2000

 

0x29

Compelled/Indefinite inpulsing FWD R2 digits received

20

 

0x2b

Cycle complete event wait

200

 

0x2d

Wait for next BWD R2 signal after outpulse stage 3 digits

2000

 

 

 

 

R2 Signaling Timer

0x01

Pulse Duration (15)

 

 

0x02

Pulse Delay (15)

 

 

0x03

Minimum Valid Duration (7)

 

 

0x04

Minimum Tone State Change

 

 

 

 

 

DTMF Signaling Timer

0x01

DTMF Transmit Digit Duration (6)

 

 

0x02

DTMF Transmit Inter-Digit Duration (6)

 

 

0x03

DTMF Maximum Receive 1st digit detect (2000)

 

 

0x04

DTMF Maximum Receive Inter Digit Timeout (2000)

 

 

0x05

DTMF Minimum Receive 1st digit detect (2000)

 

 

0x06

DTMF Minimum Receive Inter Digit Timeout (2000)

 

 

 

 

 

MFR1 Signaling Timer

0x01

MFR1 Transmit KP Duration (6)

 

 

0x02

MFR1 Transmit Digit Duration (6)

 

 

0x03

MFR1 Transmit Inter-Digit Duration (6)

 

 

0x04

MFR1 Minimum Receive KP Duration (5)

 

 

0x05

MFR1 Minimum Receive Digit Duration (3)

 

 

0x06

MFR1 Maximum Receive KP Duration (1000)

 

 

0x07

MFR1 Minimum Receive Inter-DigitTimeout (3)

 

 

0x08

MFR1 Maximum Receive Inter-DigitTimeout (3)

 

 PPL Filter/Timer Value:

Each PPL Filter/Timer Selection can be modified. Click in the PPL Filter/Timer Value field and the following pop-up will appear. Enter a value which will be in milliseconds

 

Return to Documentation Home I Return to Sangoma Support