Dialogic IMG - IMG 1010 - Filter/Timer Configure

Dialogic IMG - IMG 1010 - Filter/Timer Configure

Description:

Use this pane to adjust CAS trunk and line signaling filters and timers. Typically this is only required when the trunk or line that the IMG is connected to is not operating to line interface specifications. All timers and filters are set to default values based on industry specifications when the channel trunk type is configured.

Accessing this Pane:

Dialogic IMG EMS -> Signaling -> <Variant Name> -> Filter/Timer Configure

Maximum Objects:

No Limit

Previous Configuration Required:

IMG 1010 - Signaling Variant

Related Topics:

IMG 1010 - Configuring CAS 

Filter / Timer Pane (T1): (E1 shown below)

Field Descriptions:

PPL Filter/Timer Type:

In CAS the only selection is Generic Protocol Timer.

PPL Filter/Timer Selection (T1):

Below is a table which displays the Filter Timer Type along with the PPL number and selections for reference.

PPL Filter Type

PPL Filter/Timer Number

PPL Filter/Timer Selection

E&M

FXS Loopstart

Generic Protocol Timer

0x01

Preseize

10

 

 

0x02

Inseize

15

20

 

0x03

Modified Incoming Release

70

70

 

0x04

Modified Outgoing Release

70

70

 

0x05

Normal Incoming Release

70

70

 

0x06

Normal Incoming Release with Flash

102

102

 

0x07

Normal Outgoing Release

70

60

 

0x08

Normal Outgoing Release with Flash

102

102

 

0x09

Post Inseize Acknowledgement

 

 

 

0x0a

Outseize Acknowledgement

10

10

 

0x0b

Outseize Answer

35

 

 

0x0c

Outseize Dial Signal End

4

 

 

0x0d

First Release

70

15

 

0xe

ANI Request Off-Hook

20

 

 

0x15

Inseize Complete

 

 

 

0x16

Post Inseize Complete

 

 

 

0x17

Start Normal Outgoing Release

0

 

 

0x18

Start Normal Incoming Release

0

 

 

0x19

Outseize Acknowledgement

500

64,0000

 

0x1a

Outseize Answer

10,000

 

 

0x1b

Guard Timeout

70

32,000

 

0x1c

Release

32,000

 

 

0x1d

Glare Detection

10

30

 

0x1e

Minimum Flash

30

100

 

0x1f

Maximum Flash

100

 

 

0x20

Start Dial Minimum Wink

10

 

 

0x21

Start Dial Maximum Wink

35

 

 

0x22

Minimum Delay Dial Signal

14

 

 

0x23

Maximum Delay Dial Signal

400

 

 

0x24

Post Start Dial Signal Outpulse Delay

8

 

 

0x25

Wink 2 Minimum Receive Duration

10

 

 

0x26

Wink 2 Maximum Receive Duration

50

 

 

0x27

Wink 2 Minimum Post Outpulse Delay

10

 

 

0x28

Wink 2 Maximum Post Outpulse Delay

350

 

 

0x29

Wink 2 Maximum Receive Detection

1,150

 

 

0x2a

Wink 3 Minimum Receive Duration

10

 

 

0x2b

Wink 3 Maximum Receive Duration

60

 

 

0x2c

Wink 3 Minimum Post Outpulse Delay

10

 

 

0x2d

Wink 3 Maximum Post Outpulse Delay

350

 

 

0x2e

Wink 3 Maximum Receive Duration

400

 

 

0x2f

Wink 4 Minimum Receive Duration

10

 

 

0x30

Wink 4 Maximum Receive Duration

35

 

 

0x31

Wink 4 Minimum Post Outpulse Delay

10

 

 

0x32

Wink 4 Maximum Post Outpulse Delay

350

 

 

0x33

Wink 4 Maximum Receive Detection

400

 

 

0x34

Wink 5 Minimum Receive Duration

10

 

 

0x35

Wink 5 Maximum Receive Duration

35

 

 

0x36

Wink 5 Minimum Post Outpulse Delay

10

 

 

0x37

Wink 5 Maximum Post Outpulse Delay

350

 

 

0x38

Wink 5 Maximum Receive Detection

400

 

 

0x39

Wink 6 Minimum Receive Duration

10

 

 

0x3a

Wink 6 Maximum Receive Duration

35

 

 

0x3b

Wink 6 Minimum Post Outpulse Delay

10

 

 

0x3c

Wink 6 Maximum Post Outpulse Delay

350

 

 

0x3d

Wink 6 Maximum Receive Duration

400

 

 

0x3e

Wink 7 Minimum Receive Duration

10

 

 

0x3f

Wink 7 Maximum Receive Duration

35

 

 

0x40

Wink 7 Minimum Post Outpulse Delay

10

 

 

0x41

Wink 7 Maximum Pulse Outpulse Delay

350