DMG Integration with PBXs
Dialogic Media Gateways are designed and tested for PBX interoperability with the installed base of enterprise communications systems. They are also tested and approved for use with Microsoft® Unified Communications. The general use configuration guides and PBX interoperability matrix below provide guidance and configuration information (where available) for many different PBX vendors and models
Skype for SIP (Skype SIP trunking)
Dialogic® Media Gateway Skype for SIP Configuration Guide
3CX
DNS Server Install on Windows 2003 -
3CX + DMG1000 Configuration Guide -
3CX + DMG2000 Configuration Guide -
3CX + DMG4000 Configuration Guide -
General Use Dialogic® Media Gateways Configuration Guides:
Dialogic® 2000 Media Gateway Series: Installation and Configuration Note for Microsoft® Lync Server 2010 -
Dialogic® 2000 Media Gateway Series: Installation and Configuration Note for Microsoft® Office Communications Server 2007 R2 -
Dialogic® 3000 / 4000 Media Gateway Series – Quick Start Configuration Guide -
Dialogic® 4000 Media Gateway Series - Generic PBX Configuration Guide -
Interoperability and Configuration Guides for using Dialogic Media Gateways with Office Communications Server 2007:
PBX BRAND | PBX MODELS | DIALOGIC MEDIA GATEWAYS | PROTOCOLS | OCS CONFIGURATION GUIDES |
Alcatel | Omni PCX Enterprise | DMG2000 Series (all models) | E1 QSIG |
|
Alcatel | Omni PCX Enterprise | DMG2000 Series (all models) | T1 QSIG |
|
Avaya | S8500 | DMG2000 Series (all models) | E1 QSIG |
|
Avaya | S8500 | DMG2000 Series (all models) | T1 QSIG |
|
Avaya | S8500 | DMG4000 Series (all models) | T1 QSIG |
|
Ericsson | MD110 | DMG2000 Series (all models) | E1 QSIG |
|
Mitel | 3300 ICP | DMG2000 Series (all models) | E1 QSIG |
|
Mitel | 3300 ICP | DMG2000 Series (all models) | T1 QSIG |
|
Mitel | 3300 ICP | DMG4000 Series (all models) | E1 QSIG |
|
Mitel | SX-2000 | DMG2000 Series (all models) | T1 QSIG |
|
Mitel | SX-2000 | DMG4000 Series (all models) | T1 QSIG |
|
NEC | NEAX 2400 IPX | DMG4000 Series (all models) | T1 QSIG |
|
Nortel | CS-1000M | DMG2000 Series (all models) | E1 QSIG |
|
Nortel | Succession | DMG2000 Series (all models) | T1 QSIG |
|
Nortel | Option 11c | DMG2000 Series (all models) | E1 QSIG |
|
Nortel | Option 11c | DMG2000 Series (all models) | T1 QSIG |
|
Nortel | Option 11c | DMG4000 Series (all models) | T1 QSIG |
|
Siemens | Hipath 4000 | DMG2000 Series (all models) | E1 QSIG |
|
Siemens | Hipath 4000 | DMG2000 Series (all models) | T1 QSIG |
|
PBX BRAND | PBX MODELS | DIALOGIC MEDIA GATEWAYS | PROTOCOLS | LEVEL |
Alcatel | Omni PCX 4400 | DMG1008LS / DMG1004LS | Analog - serial | Lab Tested |
Alcatel | Omni PCX 4400 | DMG2000 Series (all models) | T1-QSIG, E1-QSIG | Lab Tested |
Alcatel | Omni PCX 4400, 4410, 4199 | DMG3000 (all models) | BRI-QSIG | Field Tested |
Alcatel | Omni PCX 4400, 4410, 4200 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Avaya | Definity G3 | DMG2000 Series (all models) | T1-CAS | Lab Tested |
Avaya | Definity G3 | DMG1008DNI | Digital Set Emulation |
|
Avaya (Lucent) | Definity | DMG3000 (all models) | BRI-QSIG | Field Tested |
Avaya (Lucent) | Definity | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Avaya (Tenovis) | Integral 3 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Avaya (Tenovis) | I55 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Avaya (Tenovis) | Integral Enterprise | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Avaya | S8100 | DMG1008DNI | Digital Set Emulation | Lab Tested |
Avaya | S8300 | DMG1008DNI | Digital Set Emulation | Lab Tested |
Avaya | S8500 | DMG1008DNI | Digital Set Emulation | Lab Tested |
Avaya | S8X00 | DMG2000 Series (all models) | E1 QSIG |
|
Avaya | S8X00 | DMG2000 Series (all models) | T1 CAS In Band |
|
Avaya | S8X00 | DMG2000 Series (all models) | T1 QSIG | |
Avaya | S8700, S8710 | DMG1008DNI | Digital Set Emulation | Lab Tested |
Avaya | 5ESS | DMG2000 Series (all models) | T1-NI2, T1-5ESS | Lab Tested |
DeTeWe | OpenCom 1000/1010 | DMG3000 (all models) | BRI-QSIG | Field Tested |
DeTeWe | OpenCom 1000/1011 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Ericsson | MD110 | DMG1008LS / DMG1004LS | Serial MD110 |
|
Ericsson | MD110 | DMG2000 Series (all models) | E1 QSIG |
|
Ericsson | MD110 | DMG3000 (all models) | BRI-QSIG | Field Tested |
Ericsson | MD110 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Ericsson | MD110 Mixed Mode | DMG3000 (all models) | BRI-QSIG | Field Tested |
Ericsson | MD110 Mixed Mode | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Ericsson | BP128 | DMG1008LS / DMG1004LS | Analog, Serial | Field Tested |
Ericsson | BP250 | DMG2000 Series (all models) | E1-QSIG | Field Tested |
Ericsson | BP250 (Q.SIG Conform) | DMG3000 (all models) | BRI-QSIG | Field Tested |
Ericsson | BP250 (Q.SIG Conform) | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Ericsson | BP250 (ETSI Conform) | DMG3000 (all models) | BRI-QSIG | Field Tested |
Ericsson | BP250 (ETSI Conform) | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Fujitsu |
| DMG1008LS / DMG1004LS | Analog In Band DTMF | Field Tested |
Hitachi |
| DMG1008LS / DMG1004LS | Analog In Band DTMF | Field Tested |
Intecom | PointSpan M6880 | DMG1008LS / DMG1004LS | Analog In Band DTMF | Lab Tested |
Intecom |
| DMG2000 Series (all models) | T1-CAS | Field Tested |
Matra | 65XX | DMG3000 (all models) | BRI-QSIG | Field Tested |
Matra | 65XX | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Mitel | 3300 | DMG2000 Series (all models) | E1 QSIG |
|
Mitel | 3300 | DMG2000 Series (all models) | T1 QSIG |
|
Mitel | 3300 | DMG2000 Series (all models) | T1-NI2 | Lab Tested |
Mitel | SX200 | DMG1008MTLDNI | Digital Set Emulation | |
Mitel | SX-2000 S, SX-2000 VS | DMG1008MTLDNI | Digital Set Emulation | Lab Tested |
Mitel | SX-2000 S, SX-2000 VS | DMG2000 Series (all models) | T1-QSIG, E1-QSIG, T1-NI2 | Lab Tested |
NEC | NEAX2400, NEAX 2400 IPX, NEAX2000IVS2 | DMG1008DNI | Digital Set Emulation | Lab Tested |
NEC | NEAX 2400 IPX | DMG2000 Series (all models) | T1 QSIG | |
NEC | NEAX2400IMX | DMG2000 Series (all models) | T1 CAS MCI Serial | |
NEC | NEAX2400IPX,NEAX2400IMX | DMG1008DNI | Digital Set Emulation | |
Nortel | CS1000 | DMG2000 Series (all models) | E1 QSIG | |
Nortel | CS1000 | DMG2000 Series (all models) | T1-QSIG | Lab Tested |
Nortel | CS1000M, S, E | DMG1008DNI | Digital Set Emulation | Lab Tested |
Nortel | Meridian Option 11 | DMG2000 Series (all models) | T1-CAS, T1-QSIG, E1-QSIG, T1-NI2 | Lab Tested |
Nortel | Meridian 11C | DMG1008DNI | Digital Set Emulation | |
Nortel | Meridian 11C | DMG2000 Series (all models) | T1 QSIG | |
Nortel | Meridian 21 | DMG1008DNI | Digital Set Emulation | Lab Tested |
Nortel | Meridian 21A | DMG1008DNI | Digital Set Emulation | Lab Tested |
Nortel | Meridian 51C | DMG1008DNI | Digital Set Emulation | Lab Tested |
Nortel | Meridian 61C | DMG1008DNI | Digital Set Emulation | Lab Tested |
Nortel | Meridian 81C | DMG1008DNI | Digital Set Emulation | Lab Tested |
Nortel | Meridian 11C | DMG2000 Series (all models) | E1 QSIG | |
Nortel | Meridian | DMG3000 (all models) | BRI-QSIG | Field Tested |
Nortel | Meridian | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Nortel | DMS-10, DMS-100 | DMG1008LS / DMG1004LS | Analog, Serial | Field Tested |
Nortel | DMS-100 | DMG2000 Series (all models) | T1-NI2, T1-DMS100 | Lab Tested |
Nortel | Option 11C mini | DMG1008DNI | Digital Set Emulation | Lab Tested |
Philips | Sopho | DMG2000 Series (all models) | E1-QSIG | Lab Tested |
Rolm (Siemens) | 9751 | DMG1008RLMDNI | Digital Set Emulation | |
Rolm (Siemens) | 8000, 9000, 9751 | DMG1008LS / DMG1004LS | Analog In Band DTMF | Lab Tested |
Siemens | Hicom 150E | DMG1008LS / DMG1004LS | Analog In Band DTMF | Field Tested |
Siemens | Hicom 150E | DMG3000 (all models) | BRI-QSIG | Field Tested |
Siemens | Hicom 150E | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Siemens | Hicom 300 | DMG1008DNI | Digital Set Emulation | |
Siemens | Hicom 300 | DMG2000 Series (all models) | T1 CAS In Band | |
Siemens | Hicom 300 | DMG3000 (all models) | BRI-QSIG | |
Siemens | Hicom 300 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Lab Tested |
Siemens | Hicom 300ECS | DMG1008DNI | Digital Set Emulation | Lab Tested |
Siemens | Hicom 300ECS | DMG2000 Series (all models) | T1-CAS | Lab Tested |
Siemens | Hicom 300E (Euro) | DMG1008LS / DMG1004LS | Analog In Band DTMF | Lab Tested |
Siemens | Hicom 3000 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Siemens | Hicom 3000 | DMG2000 Series (all models) | T1-QSIG, E1-QSIG | Field Tested |
Siemens | HiPath 4000 | DMG1008DNI | Digital Set Emulation | Lab Tested |
Siemens | HiPath 4000 | DMG1008LS / DMG1004LS | Analog In Band DTMF | |
Siemens | HiPath 4000 | DMG2000 Series (all models) | T1 QSIG | |
Siemens | HiPath 4000 | DMG2000 Series (all models) | E1-QSIG, T1-NI2 | Lab Tested |
Siemens | HiPath 4000 | DMG3000 (all models) | BRI-QSIG | |
Siemens | HiPath 4000 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Lab Tested |
Tenovis | Integral 3 | DMG2000 Series (all models) | E1-QSIG | Lab Tested |
Tenovis | Integral 3 | DMG4000 (all models) | T1-QSIG, E1-QSIG | Field Tested |
Toshiba | CTX | DMG1008LS / DMG1004LS | Analog Serial | |
Toshiba | CTX | DMG1008LS / DMG1004LS | Analog In Band DTMF |
Explanation of PBX Interoperability Status:
The PBX interoperability matrix above includes a column – labeled “Level” – indicating the current status between the listed PBX, media gateway, and Microsoft® Exchange Server 2007 or Microsoft Office Communications Server 2007. The explanation for each of the various status codes is as follows:
Download Configuration Guide
Dialogic has developed a specific configuration guide for integrating the listed PBX with Microsoft Exchange Server 2007 Unified Messaging using the indicated gateway and PBX protocol. The configuration guide is applicable for use with Microsoft Office Communications Server 2007 as well, in tandem with the generic configuration note for Microsoft Office Communications Server 2007.Lab Tested
Dialogic has successfully lab tested interoperability between the listed PBX, gateway and protocol with either Microsoft Exchange Server 2007 or Microsoft Office Communications Server 2007. Configuration notes may be work in progress for posting at a later date.Field Tested
Dialogic or an integration partner has successfully deployed the listed gateway with the listed PBX and Microsoft Exchange Server 2007 or Microsoft Office Communications Server 2007.