Initial WebGUI connection
SBCÂ factory settings: Â Primary Ethernet port 0 is set to a static IP address.Â
Proceed to connect to the SBC Appliance via Laptop’s web browser.
Connect the Primary Signaling Port 0  to a LAN Switch
Connect Laptop to LAN Switch
Configure Laptop to IP address: 192.168.168.254/24
Using Laptop web browser goto URL:
http://192.168.168.2
orhttps://192.168.168.2
Login via
Username: root, Password:Â sangoma
SBCÂ WebGUI Login Screen
Â
Â
Default Credentials
Username: root
Password:sangoma
Â
Make sure to change the default password right away. Change Password Section
Â
Â
SBCÂ WebGUI Initial Status
On the very first login, the WebGUI will provide you an overview of Sangoma SBC configuration status.
Â
Â
Â
The top of the WebGUI screen contains Information dialogs that are used to provide important messages to the user.
At a quick glance we can see that the SBC isÂ
Not started
And that Configuration is not complete
Â
Â
Below the Information Dialogs, the Configuration Checklist indicates what are the minimum configuration steps necessary to get the SBC running.