SS7 - Nodes - Remote Node

The Remote Node object assigns an already configured physical node (IMG 2020) to be a Remote SS7 server node. When configuring SS7 functionality, the Remote Node can be configured to handle remote CICs. These CICs are controlled by the SS7 server that has obtained the active SS7 server role. To create the Remote Node object, right click on the SS7 Nodes object and select New Remote.

Web GUI Page

Dialogic > SS7 > SS7 Network > SS7 Nodes > New Remote

 

Maximum Objects

Up to 4 remote nodes can be created when SS7 Redundancy is configured and up to 5 nodes when SS7 redundancy is not being configured. The Multi Node feature supports configuring up to 6 total nodes.

Related Topics and Dependencies

The Remote Node is created under the SS7 Nodes object. The Remote Node object assigns the node selected from the drop down menu to be a Remote SS7 server node. The Remote Node will process the data through any CICs that are configured on it. However, the CICs will be controlled by either the Primary or Secondary SS7 Server node. Whichever is active. The Primary SS7 server node should be created before any Remote SS7 server nodes. Refer to the links below for more information on each of the Node Types configured under the SS7 Nodes object.

SS7 - Nodes

SS7 - Nodes - Secondary Node

SS7 - Nodes - Primary Node

Configure SS7

Configure SS7 Redundant Nodes 

Field Descriptions

Node Name

The Node Name field contains drop down menu displaying all the IMG 2020 nodes created and configured within the Web GUI application. Select from the drop down menu, the node that will have the remote CICs configured on it. This node will be assigned as the Remote Node when SS7 Redundancy is being configured.

Network ID

Up to four separate SS7 Network objects/Networks can be configured. Each SS7 Network can have an SS7 Primary server node as well as a Secondary SS7 server node configured within it. The Network ID field selects which SS7 network (IMG 2020 nodes as SS7 servers) created and configured will control the CICs configured on the Remote Node. Select the SS7 Network ID from the drop down menu.

Return to Documentation Home I Return to Sangoma Support