IMG 1010 - Configuring H.323 Signaling
Â
Prerequisites:
Procedure:
Right-click Physical IMG and select New Signaling.
Right-click Signaling and select New H.323. The IMG 1010 - H.323 Signaling Object pane appears. Complete the fields as noted below.
H.323 ID
H.323 Signaling  IP Address
H.245 Tunneling (if required). This enables inbound tunneling. Outbound tunneling can be enabled in the IP Bearer Traffic Profile used for outbound calls. See IMG 1010 - H245 Tunneling.
The following fields will be green and currently have only one option. They are not configurable:Â
H.323 Variant (ITU)
H.323 Version (H.323 V2)
H.323 Terminal Type (GW with no MC) Â
The fields listed below are only required if you are connecting to an external gatekeeper. The external Gatekeeper is configured with the IMG 1010 - External Gatekeeper pane.
Gatekeeper Support (change to Enable)
E.164 Number
Gateway URL
Gateway EMail
Gateway Technology Prefix (if the external gateway requires one)
To change the default H.323 timers, right-click the H.323 Signaling entry and select New H.323 Timers. Refer to IMG 1010 - H.323 Timers pane reference.
Gateway Discovery/Registration
You can Discover and Register with a gatekeeper manually using the Gateway buttons in the H.323 Signaling pane. To automatically Discover and Register with a gatekeeper, enable Gatekeeper Auto Discovery in the IMG 1010 - External Gatekeeper pane.
Related Topics:
IMG 1010 - Configuring IP Bearer Profiles
IMG 1010 - Adding an External H.323 Gatekeeper
IMG 1010 - External Gatekeeper
Â