If transferring the file using sFTP, the sFTP functionality must first be enabled on the IMG 2020. Refer to the SFTP Server topic for information on this.

...

  • From the Web GUI, delete all DNS Client objects.

  • From the Web GUI, delete all DNS Server objects.

  • From the Web GUI, delete all ENUM Server Set objects.

  • Save the current configuration by clicking on the Save ICON. A Save File dialog box will appear. In the field labeled File Name, enter a name that will identify the updated file being saved for the 2.2 software upgrade. Click on the Save button to save the file. One thing to note is the latest save just initiated will not include the objects displayed above.

  • Continue on with the upgrade process as described in the sections below. Once the upgrade has completed, the files that were deleted can now be re-added using the updated format. Refer to the DNS Servers, DNS Clients and ENUM Server topics for information on configuring these objects.

...

  • If using an SD card reader/writer, first remove the SD card from the front of the IMG 2020 chassis and insert it into the SD reader/writer. Copy and paste or drag and drop the new binary file to the SD card.

  • Edit the file=bdn2020_ver230xxx_id0201.bin line in the bootup.cfg file so the new software build version number is displayed in the "xxx" section of that line.

  • If a new license file is being loaded, copy the license file to the directory on the SD card that contains the system software file.

  • Remove the SD card from the SD reader/writer and reinsert into the IMG 2020.

  • Restart the IMG 2020 by either power cycling the IMG 2020 or clicking on the Reset IMG 2020 button on the IMG 2020 physical node object.

  • After the IMG 2020 has been reset it will go through a series of diagnostics and the LEDs on the front panel will blink in a specific sequence to indicate it is in the loading process. Refer to the Software Install - SD Card for additional LED and software loading information.

  • Once software has downloaded, the IMG 2020 will utilize the .dat file to re-configure the IMG 2020 with the newer software.

  • Open up a browser and enter the IP address used to connect to the IMG 2020. Enter the logon credentials when prompted.

  • Once the Web GUI has opened, verify the correct version of software is loaded by clicking on the IMG 2020 physical node object and verify the build of software displayed in the Software Version field is the updated version.

  • Verify all spans that were in service prior to upgrade return to in-service state.

  • Verify calls are being processed to all trunk groups.

...

  • Using sFTP, transfer the new software file to the FTP server. The software file must be transferred in binary mode.

  • Edit the naming of the file just transferred to equal the name given to the file in the bootup.cfg file. If the Software Loading installation procedures in this documentation were followed, modify the file naming to the following below:
    bdn2020_id0201.bin

  • If a new license file is being loaded, ftp the license file to the folder that contains the system software file.

  • Restart the IMG 2020 by either power cycling the IMG 2020 or clicking on the Reset IMG 2020 button on the IMG 2020 node object.

  • After the IMG 2020 has been reset it will go through a series of diagnostics and the LEDs on the front panel will blink in a specific sequence to indicate it is in the loading process. Refer to the Software Install - FTP/SD Card for additional LED and software loading information.

  • Once software has downloaded, the IMG 2020 will use the .dat file to re-configure the IMG 2020 with the newer software.

  • Open up a browser and enter the IP address used to connect to the IMG 2020. Once the Web GUI has opened, verify the correct version of software is loaded by clicking on the IMG 2020 physical node object and verify the build of software displayed in the Software Version field is the updated version.

  • Verify all spans that were in service prior to upgrade return to in-service state.

  • Verify calls are being processed to all trunk groups.

...