# mdadm will ask which MD arrays are needed for the root fs. Go with the default (all)

yum install mdadm initramfs-tools vim

 

# Add raid1 to /etc/modules

echo "raid1" >> /etc/modules

 

# Regenerate initrd.img file

mkinitramfs -o /boot/test -r /dev/mapper/pve-root

 

# Rename old img file (replace .x for whatever kernel version you are using)

mv /boot/initrd.img-2.6.18-2-pve /boot/initrd.img-2.6.18-2-pve.original

 

# Rename new img file

mv /boot/test /boot/initrd.img-2.6.18-2-pve

 

# Make sure grub is setup on both hdds

grub-install --no-floppy /dev/sda

grub-install --no-floppy /dev/sdb

 

# Change UUID for (hd0,0) on /boot/grub/menu.1st if your file has the UUID in it.

# This most likely involves replacing the root UUID=XXXXX line with root hd(0,0)

# nano /boot/grub/menu.1st

 

# Change UUIDs for proper md0 devices on /etc/fstab if your file has the UUID in it.

# Now do the same thing for the /etc/fstab file.

# Replace the UUID=XXXXXXXXX /boot ext3 defaults 0 1 line with /dev/md0 /boot ext3 defaults 0

# nano /etc/fstab

 

# Clone the partition table from 1st drive to 2nd

sfdisk -d /dev/sda | sfdisk --force /dev/sdb

 

# Create md devices with second drive only

mdadm --create /dev/md0 --level=1 --raid-devices=2 missing /dev/sdb1

mdadm --create /dev/md1 --level=1 --raid-devices=2 missing /dev/sdb2

 

# Save new mdconf file

mdadm --detail --scan >> /etc/mdadm/mdadm.conf

 

# Get boot device setup

mkfs.ext3 /dev/md0

mkdir /mnt/md0

mount /dev/md0 /mnt/md0

cp -ax /boot/* /mnt/md0

umount /mnt/md0

umount /boot; mount /dev/md0 /boot

sfdisk --change-id /dev/sda 1 fd

mdadm --add /dev/md0 /dev/sda1

 

# Setup data device

pvcreate /dev/md1

vgextend pve /dev/md1

 

# this step takes a LOOOOONG time

pvmove /dev/sda2 /dev/md1

vgreduce pve /dev/sda2

sfdisk --change-id /dev/sda 2 fd

mdadm --add /dev/md1 /dev/sda2

 

Related content

Rebuilding Software Raid
Rebuilding Software Raid
More like this
Step By Step Debian 12 Installation
Step By Step Debian 12 Installation
More like this
FreePBX HA Custom Installation procedure
FreePBX HA Custom Installation procedure
More like this
Support Services - How to run Ultimate boot cd on Switchvox to test hard drives and memory
Support Services - How to run Ultimate boot cd on Switchvox to test hard drives and memory
More like this
Session Border Controller - SBC Swapping faulty SSD Raid1
Session Border Controller - SBC Swapping faulty SSD Raid1
More like this
Installing FreePBX with the Official Distro
Installing FreePBX with the Official Distro
More like this
Unable to render {include} The included page could not be found.