Element Management Server Specifications

 

When configuring a single node using the direct connect scenario, the node can be configured through use of a single Web UI application running on a Web Browser. If a user wants to configure numerous IMG 2020 nodes using a single Web Browser and Web UI application, Dialogic's EMS software must be utilized. In this scenario, the IMG 2020 nodes communicate with the Web UI application through the EMS software. The EMS software needs to be running on either a Virtual Machine running Red Hat Enterprise Linux or a separate Linux Server running Red Hat Enterprise Linux. Dialogic can supply a customer with either a VM image with the EMS software installed or a separate Linux Server with the EMS software installed. The information below displays the specifications of the Linux Server with the EMS software installed.

Important!!! If purchasing a single node direct connect system and the plans are to expand to multiple nodes, initially purchasing a Multi Node setup with EMS software will make it easier to expand to more than one node. The configuration used in the single node scenario can not be used in the multi node setup and the node will need to be completely re-configured.

Server

Specifications

Server

Specifications

Model

BDN-EMS-2930/2931

Processor

1.8 GHz Quad Core (Intel Xeon E5-2403)

L2 Cache

10 MB Cache

Memory

2 GB (2X 1GB) 1333 Mhz Dual Rank

Hard Drive

(2) 500 GB 7.2K RPM SATA

Optical Drive

DVD+/-RW SATA

Power Supply

(2) AC 350 Watts

Rack Mount Kit

Included (19")

Ethernet Adapter

1GB on-board Broadcom 5720 Dual Port

 

Physical Specifications

Server

Specifications

Server

Specifications

Height

1U Form Factor, 1.7" (4.28 cm)

Depth

  • Front Bezel = 1.4" (3.5 cm)* Chassis with Redundant PS with handles = 25.3" (64.23 cm)

  • Total length including front bezel =  27" (68.51 cm)

Width

17.1" (43.4 cm)

Weight

  • Maximum Weight = 42.55 lb (19.3 kg)

  • Shipping weight as configured = 38.85 lbs (Includes shipping box and server)

  • Weight as configured = 25.10 lbs


Power Specifications

The power and cooling provided from the site must fall within the specifications listed below. In general, a typical office environment satisfies these conditions. A temperature-controlled environment is preferable.

Parameter

BDN-EMS-2930

Parameter

BDN-EMS-2930

Vin (voltage)

100 - 240 vac

Iin (current)

2.4A - 4.8A Max (Nominal xxx)

Vin (frequency)

50/60 Hz

Heat Dissipation

1356 BTU's/hr

 

Environmental Specifications

Storage Requirements

Parameter

Range

Parameter

Range

Temperature

-40° F to 149° F (-40° C to 35° C)

Relative Humidity (Non Condensing)

5% to 95%

Altitude

-50 ft to 39,370 ft (-15.2m to 12,000m)

 

Operating Requirements

Parameter

Range

Parameter

Range

Temperature

50°F to 95°F (10°C to 35°)

Relative Humidity (Non Condensing)

10% to 80%

Altitude

-50 ft to 10,000 ft (-15.2m to 3048m)

 