Web GUI - Functionality

 

 

Below displays and describes the different functionality of the Web GUI. The Web GUI is used for configuration, provisioning and monitoring of the IMG 2020. The Web GUI is opened up in a web browser using one of the supported browsers in the table below.

 

Web Browser

Supported

Mozilla FireFox

Yes

Microsoft Internet Explorer

Yes

Google Chrome

Yes

Safari

No (Not as of Release 2.2)

 

When working within the Web GUI, if any javascript changes such as adding or deleting entries in the object table tab are made, it is possible the Web GUI could display some erroneous results. In this case, the Web browser cache may need to be cleared. Clearing the web browser cache usually cleans up these issues.


Connecting to IMG 2020 through Web GUI

Connecting to the IMG 2020 can be accomplished through either a single node direct connection or through a multi node connection. Refer to the correct scenario below.

Single Node Direct Connect

  • Open one of the supported Web Browsers from table above. In the procedure below, Mozilla Firefox was used, although any of the Web Browsers supported from table above would use the same procedure.

  • If connecting to a single node direct connect scenario, enter the IP address of the IMG 2020 into the browsers location bar and press <Enter> key. The IP address of the IMG 2020 is the IP address in the yiaddr= line in the bootup.cfg file.


Multi Node Connection through Virtual Manager and EMS Installation

  • Open one of the supported Web Browsers from table above. In the procedure below, Mozilla Firefox was used, although any of the Web Browsers supported from table above would use the same procedure.

  • If connecting to a Multi Node setup, enter the IP address given to the Virtual Manager. If IP address is not known, refer to the Software Install Overview (Multi-Node) topic. Refer to screen capture below.

 

The Login page dialog box appears. Enter the User and Password information. See screen capture below.

 

The default user and password given to the IMG 2020 is displayed below.

 

 

Default User and Password

User

dialogic

Password

Dial0gic (Capital D, Zero for O)

 

In the Login Dialog box, there is a box labeled Request Configuration Rights and by default has a check mark in it. By checking this box, this allows a user to both log into the Web GUI and request permissions to be able to configure the IMG 2020 using the Web GUI. If another user is logged into the IMG 2020 a dialog box will appear displaying Another user owns permission. To gain configuration rights the user must get the existing user to relinquish configuration rights -or- if the user logging in has administrative rights, that user can force the existing user off by clicking on the Remove Edit Mode ICON. Refer to the Edit Mode Icon section below for more information on seizing Administrative rights.

 

  • If this is the first time logging into IMG 2020 through the Web GUI the Dialogic object will be the only object displayed. If the Direct Connect Single Node scenario is being employed, right click on the Dialogic object and select New IMG 2020. The IMG 2020 physical node screen will appear. Select an ID from drop down menu. In the Name field, enter a Name that will identify this node. Refer to the Physical Node - Direct Connect topic for information on configuring the remaining fields.

    If however the Multinode scenario is being employed, as described above, right click on the Dialogic object and select New IMG 2020. The IMG 2020 physical node object will appear. In the Name field, enter a Name that will identify this node. In the IP address field, enter the IP address of the node that you would like to connect to. Refer to the Physical Node - Multinode topic for information on configuring the remaining fields.

  • Click on commit icon from the configuration tab.

  • The unpopulated fields will now automatically be populated with information from the IMG 2020. Once the node is created and committed the configuration of the IMG 2020 can now be started.

Web GUI Toolbar

Below is screen capture of the Web GUI toolbar and an explanation of each ICON located in the Web GUI.

 

 

Logged in as:

On the right side of the Toolbar, a Logged in as text displays the user that is currently logged in to the IMG 2020. Click on (Logout) and the user is automatically logged out of the system.

 

File Tab

Icon

Description

Select New from the File menu when there is already an existing configuration and a new configuration will be started. When selecting New and there is already an existing configuration, a confirmation dialog box will appear displaying the following:

System will reboot, start a new configuration?

Select Yes if a new configuration is going to be created.

The nodes will need to reboot and reload software before configuration can begin.

Select Open from the File menu to open an existing configuration. After selecting open, an Open File: box will appear which displays all the configuration files (.dat) existing on the SD card. Click on the configuration file to be loaded and click on the Open button and the file selected will be loaded.

Select Save from the File menu to save the configuration file currently being configured. After selecting Save, a Save File: dialog box will appear with all .dat files saved to the SD card. Either select the file from the list or enter a different name and click on the Save button. The file is saved to the SD card with a .dat extension.

Select Delete from the File menu to delete an existing configuration file (.dat) from the SD Card. After clicking on Delete, a Delete File: box will appear. Select the file to be deleted and select click on the Delete button.

When clicking on the Export DBs Icon, the IMG 2020 exports all its databases to the SD Card into a directory labeled Databases. The Export DBs icon should only be used when specifically asked by Dialogic Support Personnel to do so. Once the Databases directory is created on the SD card, it can then be sent to Dialogic Support Personnel for Analysis.

 

Configuration Tab

Icon

Description

Commit

After entering the configuration information on an individual object, the object must first be committed which is to send the configuration from the Web GUI down to the IMG 2020. To commit an object, click on the object entry in the configuration tree and then click on the commit icon in the menu bar. This will send the configuration for that object to the IMG 2020. The object is fully committed when the configuration tree icon is displayed with a check mark which signifies object has been fully configured. For more information on the state of the icons, refer to Web GUI Indicators topic.

Delete

Delete the object currently selected/highlighted in the Configuration Tree Pane.

Undo

When an object has been created, there are individual fields located in the configuration and provisioning pane of the object. These fields need to be individually configured. If a change is made to one or more fields, the option of reverting back to the previous state is given by selecting Undo Changes form the menu bar. This reverts the changes made in the Web GUI pane back to its previous value.

Expand Next Level

Expands all the objects that were collapsed under the selected/highlighted object. This will expand the objects one level down only. If there are objects that are two levels down, they will be expanded out from under the highlighted object but the object two levels down will not be expanded.

Collapse Previous

This will collapse all the objects under the highlighted object so they are now hidden under the object selected. Any objects that are two or more levels down will be rolled up under the highlighted object but will not be collapsed.

 

Management Tab

Icon

Description

Edit Mode

Edit Mode Enabled

Edit Mode Disabled

When the Edit Mode icon looks like the Edit Mode Enabled icon to the left, the user will have configuration rights. A user with configuration rights can modify and configure the objects within the Web GUI. When the Edit Mode icon is clicked on, it changes to the Edit Mode Disabled icon displayed to the left. When the icon is in the Edit Mode Disabled state, the user will not have the ability to modify or configure the objects. The objects will be grayed out and cannot be accessed in the Edit Mode Disabled state. The Edit Mode was designed so that multiple users can log into the IMG 2020 at once and depending on each ones administrative rights, only one user is allowed configuration rights at a time. In order for a user to gain configuration rights, a second user who has the configuration rights must first set the Edit mode to Edit Mode Disabled. The user who wants the administrative rights must then toggle his or her browsers Edit Mode icon to Edit Mode Enabled.This gives the user configuration rights and now he/she can modify the configuration. Refer to the Topics under the AdminManager section for more information on administrative permissions and rights.

Remove Edit Mode

Only a user with Administrative rights can use the Remove Edit Mode. If there is another user logged into the system that has configuration rights, the user with Administrative rights can remove the configuration rights from the logged in user. At this point, the user with administrative rights will also have configuration rights.

Change Password

To modify the password for the user that is currently logged into the system, click on the Password Change icon. A Password Change: dialog box will appear. Enter the existing password and then enter the new password twice. Once in the New Password field and then again in the Repeat Password field. At that point, the password for that user has been modified.When modifying a password, there are a set of complexity rules that need to be followed. Refer to the Username Password Rules topic when modifying or creating a password for a new or existing username.

To exit from the Password Change dialog box without modifying the password, enter the existing password in all three fields of the Password Change: dialog box.

 

Help Tab

Icon

Description

Click on the object Help Menu Icon and the WebHelp will open the documentation for the specific object that is currently being displayed in the Configuration and Information object pane. The topic opened up will describe the individual fields of that object and what type of values need to be entered.

Clicking on the Help Menu Icon will open up the Dialogic Technical Documentation website. From here the WebHelp can be either opened for viewing or a zip file can be downloaded to a local PC. Also, individual .pdf manuals including a Quick Start Guide and individual hardware replacement procedures can be viewed or downloaded.

Click on the About Icon and an About dialog box appears. The About box has two tabs labeled Company Info and Session Info. Refer to the information below as to the information displayed in each tab. 

Company Info Tab - The Company Info Tab displays information such as what version of software is loaded in the IMG 2020 and any contact information needed.

Session Info Tab - The Session Info Tab displays the following. Dialogic Support Personnel may ask for the values in this tab while troubleshooting an issue.

 

 

Return to Documentation Home I Return to Sangoma Support