Settings required to use X.25 over the D-Channel (known as "Digi Access")
Settings
Settings required to use X.25 over D-channel on the KPN 'Digi Access' Network in the Netherlands:
TEI=3
Speed 9600 bps
Number of Virtual Circuits (e.g. to be configured on the Eiconcard) 1 or 2
X.25 Addresses
X.25 over D-channel addresses are related to the main ISDN phone number.
Example:
For an ISDN line in The Hague with the phone number 070 427 94 37 the X.25 address would be: 31704279437
31 is the addition of the country code for the Netherlands
70 is the area code without the leading '0'