Dialogic IMG - IMG 1010 - Creating Custom SS7 Variants

Dialogic IMG - IMG 1010 - Creating Custom SS7 Variants

Ā 

Ā 

Create a new SS7 signaling variant

  • Right click IMG EMS and select New Signaling Variants.

    Ā 

  • Right click Signaling Variants and select New Signaling Variant.


    The Signaling Variant pane appears. Ā 

  • In the Variant Name field, enter a name for the variant.
    Automatically Populated Field: Variant Type = SS7.

  • In the Base Variant field, select the base variant to use for this custom variant.
    Automatically Populated Field: Variant ID = next available number in sequence.
    SeeĀ IMG 1010 - Signaling Variant for more details.

  • Right click the entry you just configured in the Configuration Tree and select New Variant Entry.


    The Variant Entry pane appears. Ā 

  • Configure fields as required.
    SeeĀ IMG 1010 - Variant Entry for more details.

Importing Variant Entries

  • To import a variant entries, store the variant file ("variantname".cfg) in the path on the Linux host. See path below:
    /opt/dialogic/IMG/config/Variant/"VariantName" (Software 10.5.1 +)
    /opt/cantata/IMG/config/Variant/"VariantName" (Software 10.3.3 to 10.5.0)
    The CSV file that loads the variant into GCEMS needs to be located on the same machine that ClientView is running on.

  • Right-click the Variant Name created and select Import Variant Entry, then select the desired file.

Related content

Dialogic IMG - IMG 1010 - Variant Provisioning
Dialogic IMG - IMG 1010 - Variant Provisioning
More like this
Signaling Variants Overview
Signaling Variants Overview
More like this
Dialogic IMG - IMG 1010 - Base Variant Parameter Pane - CAS
Dialogic IMG - IMG 1010 - Base Variant Parameter Pane - CAS
More like this
IMG 1010 - Signaling Variants
IMG 1010 - Signaling Variants
More like this

Return to Documentation Home I Return to Sangoma Support