IMG 1010 - SS7 Link Set

 

Description:

This object identifies a link set that is used to connect an SS7 stack on the physical IMG to an adjacent point code.

Accessing this Pane:

Dialogic IMG EMS-> Logical IMG-> Physical IMG-> SS7 -> SS7 Stack -> SS7 Link Set

Maximum Objects:

128 per physical IMG

Note on SS7 Functionality on the IMG 1004: With each new software release Dialogic has added new SS7 functionality to the IMG 1004. See timeline below:

  • Release 10.5.1 – Ability to act as a remote SS7 node and terminate up to four links. (F-1406)

  • Release 10.5.3 – Full SS7 functionality. (F-1446)

Related Topics:

IMG 1010 - Configuring SS7 Signaling - 10.5.1

Technical Notes:

When configuring a SS7 Link Set, the following happens:

An adjacent point code is configured for that physical IMG.

SS7 Specifications for IMG 1010 and IMG 1004:

ClientView Pane:

Field Descriptions:

Link Set ID:

This field specifies the ID of the SS7 link set. This field is automatically populated with the next available ID. The SS7 Link Set ID can be modified by selecting a different ID from the drop down menu.

APC:

The Adjacent Point Code (APC) field specifies the adjacent point code of the node that the Link Set will be communicating with. The format of the APC will follow the same rules in the SS7 stack. For example if the OPC is ITU 97, which follows the format of 3-8-3, the APC should also be running ITU 97 and should follow the format of 3-8-3. Point codes can be expressed in dotted decimal or decimal format.

Comments:

You can enter information about the Link Set such as location and type of SS7 far side (for example, New York STP).

 